H36PVN Power Vent Indoor Gas Fireplace
Page 14
XG0649 - 031511
Installation
Venting Components
The following venting components and associated Montigo part
numbers are available for the EDVWSPV58:
Connection and installation of the vent components should
adhere to the following guidelines:
■ Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue .
■ Ensure the pipe ends male to female slide in a minimum
of 1 1/2“ of overlap .
■ Ensure all runs are supported with a minimum of 3 supports
per 10’ of venting .
■ When hanging/ supporting venting, ensure that 1” clearance
is maintained on all sides to any combustible material .
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports .
■ Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots .
■ Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement .
■ All exterior joints in venting should be sealed with high heat
silicone RV230 .
Installation of the EDVWSPV58 external wall mounted power vent
module.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable .
The EDVWSPV58 Power Vent dimensions:
The EPVF58 Rough-in Frame dimensions:
9 3/4"
10 9/16"
5
9.0
11 1/16"
11 1/16"
11 1/16"
10 9/16"
5
9.0
14 1/4"
14 1/16"
1 1/2"
4 9/16"
8
12 1/8"
9 11/16"
12 5/16"
4
9 11/16"
ISOMETRIC VIEW
EPVF58 DIMS (2).pdf 1 3/7/2011 9:16:30 AM
A - Termination
EDVRSPV58
B - Rough-in Frame
EDVRSPV58F
C - Flex Sections
PLF-1 (12" Section)
PLF-2 (24" Section)
PFL-3 (36" Section)
PFL 4 (48" Section)
D - Rigid Sections
PEXT-1 (12" m/f Section)
PXT-20 (20" Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90
º
Elbow
PEL-90FF (f/f 90
º
Elbow
PEL-90FM (f/m 90
º
Elbow)
PEL-45FM (f/m 90
º
Elbow)
F - Power Cord
Harnesses
EPVH10-10 foot power cord & harness
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness