H36PVN Power Vent Indoor Gas Fireplace
Page 29
XG0649 - 031511
Operation
To Turn Off Gas To Appliance:
1 . Turn off remote switch .
2 . Remove the lower Horizontal access panel .
3 . Turn the incoming gas control valve to "Off" .
4 . Replace the lower Horizontal access panel .
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
Proflame SIT Electronic Ignition
Lighting Instructions:
Immediately call your gas supplier from a neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the Fire Department.
C. Use only your hand to push in or turn the gas control knob. Never use tools.
If the knob will not push in or turn by hand, don't try to repair it, call a qualified
service technician. Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been un
der water. Immediately
call a qualified service technician to inspect the appliance and to replace any
part of the control system, and any gas control which has been under water.
A . This appliance is equipped with an ignition system that lights
the pilot burner automatically . Do not attempt to light the pilot
by hand .
B . BEFORE LIGHTING smell all around the appliance area for
gas . Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor .
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
1 . STOP! Read the safety information above on this label .
2 . Remove the lower Horizontal access panel .
3 . Turn Incoming gas valve to the ON" position .
4 . Wait 5 minutes to clear out any gas . If you smell gas, STOP!
Follow "B" in the safety information above on this label . If you
don't smell gas, go to the next step .
5 . Turn wall switch "ON" .
6 . If the Fireplace does not light, the System will cycle through two
trials, (one minute audible clicking, thirty seconds of silence, and
then another one minute of audible clicking) . If the system locks
out due to inadequate gas flow, refer to "Troubleshooting", Page
20 .
7 . After completion of the information in the Troubleshooting section,
Repeat step 5 .
8 . If the system will not function correctly, follow the instructions
"To Turn Off Gas To Appliance" and call your service technician
or gas supplier .
EV1 (Pilot
burner)
EV2 (Main
burner)
Pilot Adjust Screw
Lockout Reset Key
Diagnostic Terminal
Power
Command (Wall
switch)
Pilot Sensor
Igniter
Ground
EV1 (Pilot burner)
EV2 (Main burner)
Gas "Out"
Gas "In"
Incoming Gas
Line, Shut-off
Valve
To fireplace
Main burner
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or death.
WARNING
XW2008