H36PVN Power Vent Indoor Gas Fireplace
Page 30
XG0649 - 031511
Maintenance
1
2
Removing the Log Grate:
The
H36PVN
is supplied with a log Grate that is fastened directly to
the base of the Fireplace . To remove the Grate, to perform certain
Maintenance functions, follow the steps described below:
Step 1.
CLOSE GAS VALVE AT INCOMING TO FIREPLACE
,
(
By
Qualified Persons ONLY, See 'Before You Start' in the Index
).
Step 2.
Remove the two (2) machine screws that hold the Pilot
Assembly in place,
Figure 20
.
(
Philips head screwdriver required
).
Figure 20. (Pilot mounting machine screws).
3
Step 3 & 4
Remove the two (2)
(RH & LH)
Base mounting
machine
screws,
Figure 20a & 20b
.
(
Philips head screwdriver required
).
Figure 20a. (LH Base mounting
machine screw).
4
Step 5.
Loosen, and Remove the Flexible Gas hose
(at fitting)
,
(turn clockwise, left to right)
Figure 20c & 20d
.
(
3/4" Open end
wrench required
).
5
5
Figure 20b. (RH Base mounting
machine screw).
5
1
2
3
4
Figure 20c. (Gas fitting).
NOTE:
Ensure all 5-steps are complete before removing Log Grate
.
(Failing to do so may damage the flexible gas hose, or mounting
hardware of the grate).
Figure 14e.
Figure 20d. (Loosening Gas fitting
on burner).
Removing the Refractory:
The
H36PVN
is supplied three (3) pieces of firebox refractory Lining .
These panels are fastened directly to the interior sides, and back
of the Fireplace firebox with brackets . To remove the brackets and
panels follow the steps described below:
Step 1.
Remove the RH-TOP machine screw that hold the Side
Refractory panel in place, then the bottom,
Figure 22
.
(
Philips head
screwdriver required
).
Step 2.
Remove the RH-Refractory panel from the firebox,
Figure
22
.
(
Place the Refractory panel somewhere safe where it will not
get chipped or damaged
).
Step 3.
Follow step1 & 2 to remove the LH-Side Refractory panel,
Figure 22
.
(
Philips head screwdriver required
).
Figure 20e. (Log Grate Removal Sequence).
Figure 22. (Removing Refractory panels).
Step 1 & 2. Figure 20.
(Pilot mounting
machine screws).
Step 3 & 4. Figure 20a.
(LH Base
mounting machine screw).
Figure
20b.
(RH Base mounting machine
screw).
Step 5. Figure 20c & 20d
. Loosen, and
Remove the Flexible Gas hose
(at
fitting)
, (turn clockwise, left to right)
(
3/4" Open end wrench required
).
LH-Panel
RH-Panel
Back-Panel
Bottom
Brackets
Top
Brackets