Figure 3b. Combustible mantle and facings. (Not to scale)
Fireplace Facing
When selecting the finish material for your fireplace, it is important
to remember the following:
If the surround of the fireplace is to be painted to match the room decor,
heat-resistant paint must be provided . Also, decorative facing must
not extend past the fireplace opening at all, because it will interfere
with the access to retainers for removal of glass door and access to
the lower compartment .
Mantels & Surrounds
National Canadian Gas Association mantel test requirements are for
fire hazard prevention to combustible materials .
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch .
XW2034
We recommend careful consideration
be given to the effects of elevated
mantel temperatures which may be in
excess of product design, for example:
candles, plastic or pictures. This can
cause melting, deformation, discolor-
ation or premature failure of T.V. radio,
and other electronic components.
CAUTION
When covering the upper metal
portion of the fireplace, (as shown,
Fig.16) with a non-combustible
material, Please
Note:
The
decorative facing materials may
be subject to temperatures in
excess of 250° F. This should be
considered when selecting facing
materials.
CAUTION
XW2036
Non-Combustible
Cement Board
(supplied by Montigo)
Non-Combustible
Cement Board
(supplied by Montigo)
Drywall/
Combustible Construction
To Ceiling
Horizontal Run
12” 11” 10” 9” 8” 7” 6” 5” 4” 3” 2” 1”
Vertical Run
Glass
16”
15”
14”
13”
12”
11”
10”
9”
8”
7”
6”
5”
4”
3”
2”
1”
Non-combustible
Header (supplied by
Montigo @ 6½”)
Combustible Construction
allowed in shaded area
First Combustible
Header @ 50"
from floor or 8”
from top of unit