19
Installation
XG0228 - 021419
45° Corner Installation 4''/7''
Attach an EEL-45 (45° elbow) directly onto the flue collar and attach it
to the EEL-45, cut the MXT-20 to suit. Slide the fireplace into position
and attach to the termination.
45° Corner Installation 5''/8''
Attach an PEL-90 (90° elbow) directly onto the flue collar and attach it
to the PEL-45, cut the PXT-20 to suit. Slide the fireplace into position
and attach to the termination.
45° or less Corner Installation 4''/7''
Use an MTO-4 termination and an MFL-1 or MFL-2/MFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
45° or less Corner Installation 5''/8''
Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
NOTE:
The PFVK01 / PFVK01F kit is available for top vent corner FLEX
application (NG only). The Kit includes a heat shield, a PFL-18 (f/f) flexible
pipe, and a termination with or without a mounting frame.
Corner Installation is available for
NATURAL GAS UNITS ONLY
NOTICE
Termination
RHS 101 (5"/8")
Heat Sheild
RHS 100 (4"7")
Heat Sheild
RHS 100 (4"7")
Heat Sheild
RHS 101 (5"/8")
Heat Sheild
PEL- 45 Elbow (5"/8")
EEL- 45 Elbow (4"/7")
PEL- 90 Elbow (5"/8")
MXT-20 (4"7")
PXT-20 (5"/8")
Flue Collar
Flue Collar
Flue Collar
Termination
Termination
Termination
Flex Section
Flex Section
Flue Collar