Page 30
H*38DF PFC Peninsula Gas Fireplace
XG0816 - 150204.1
Operation
1�
Turn off remote switch.
2�
Flip down the lower trim.
3�
Turn the switch on the gas control to "Off".
4�
Flip up the trim.
1�
STOP!
Read the safety information above on this label.
2�
Lift out the lower Horizontal access panel
.
3�
Turn switch on the gas control to OFF".
4�
Wait 5 minutes to clear out any gas. If you smell gas,
STOP!
Follow "B" in the safety information above on this
label. If you don't smell gas, go to the next step.
5�
Turn switch on the gas control to "ON".
NOTE:
This unit is
equipped with an ignition system that lights the pilot burner
automatically.
Do not attempt to light the pilot by hand�
6�
Turn on wall switch.
7�
Replace the lower Horizontal access panel.
8�
If the fireplace does not operate, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician
or gas supplier.
Honeywell Electronic Ignition
To Turn Off Gas To Appliance:
Lighting Instructions:
Gas Control Switch
Shown in ‘ON’ Position
Gas
Inlet