H*38DF ST Indoor Gas Fireplace
Page 10
XG0207 - 150204.1
Installation
Section 3: Venting
Figure 9.
Flue cover and collar removal,
Top Vented
fireplace.
Figure 9a.
Flue cover and collar installation,
Side Vented
fireplace.
Section 3-1:
CONVERTING TO SIDE VENT
Use the following instructions to convert a
H*38DF*-ST
for Rear Vent use:
1. Remove the Side flue cover and gasket (5" and 8") on the flue
outlet, as shown in
Figure 9.
2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet,
as shown in
Figure 9.
3. Install the (removed) Side flue cover and gasket material, to the
Top vent outlet. Fasten the cover with included hardware, as
illustrated
Figure 9a
.
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that
it is the highest point in the venting assembly.
It should also be
selected such that it provides the shortest vent run possible. Should
it be impossible to ensure that the termination is the highest point or
should it be impossible to meet the venting guidelines laid out below
please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting originates from the unit through the top or through
the side
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer
to the appropriate section below for installation details
All fireplaces shipped from the factory are Top vent.
Silicone application is NOT required when joining Montigo
vent pipes and components.
5” Inner Flue
Cover Plate
8” Outer Flue
Cover Plate
8” Outer
Flue Collar
5” Inner
Flue Collar
Flue Collar
8” Outer
Flue Collar
5” Inner Flue
Cover Plate
Outer Flue
Plate