XG0148 - 151123
Installation
Section:
Installing the remote On/Off Wall Switch
The H*42DF* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve
will generate its own power on a millivolt circuit or will draw its
power from an AC Connection inside the fireplace, depending on
the model of the unit. Use only low voltage wire, and DO NOT
connect any external power to the remote switch.
Refer to Figure 18, 19, or 20 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.
WARNING:
An inspection of the explosion relief flappers and door
MUST be made prior to lighting the fireplace. Faulty seal
on the door gasket and/or explosion ports will result in
products of combustion leaking into the living space and
may result in carbon monoxide poisoning.