Page 41
H*42DF Indoor Gas Fireplace
XG0148 - 151123
Maintenance
Section:
Honeywell:
The following is a troubleshooting chart of possible problems:
If your fireplace still does not operate correctly, consult your
local Montigo dealer.
All service and repairs should be performed by a qualified
Technician.
All spare parts, optional fans, and optional trim finishes are
available from your local Montigo dealer.
SIT Proflame 2:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTION
Pilot Igniter won't spark
1. Check the MAIN ON-OFF switch
(typically located below the valve
cover) and turn ON
2. Ensure main power is ON or new
batteries are installed in the remote
control and backup battery pack (if
available).
3. Check the 3.15A fuse in the control
box and replace if necessary
Pilot Igniter sparking, but
Pilot burner will not light
1. Verify the Inlet and Manifold Gas
Pressure are within acceptable limits
2. Check all connections to gas valve
3. Check connection to stepper motor
(if available)
Pilot lights , but Main
burner will not Light
1. Check and verify all wiring
connections as per the wiring
diagram.
2 . Verify the inlet and Manifold
Pressure are within acceptable limits
Pilot lights , but Main
burner will not Light and
igniter continues to spark
1. Check the Pilot Flame Sensor Rod
and clean with steel wool or similar.
2 . Check the Pilot hood and clean
with steel wool if dirty.
3. Adjust pilot flame using the pilot
adjustment screw if the pilot flame is
too long or too short (Flame should
fully engulf the sensor rod and must
be stable).
4. Check and make sure the ground
wire from the pilot is connected to
the fireplace body.
Fans not working
1. Ensure main power is ON (fireplace
may be operating on back up
batteries).
2. Check the 3.15A fuse in the control
box and replace if necessary
Troubleshooting:
SIT Nova 820:
The following is a troubleshooting chart of possible problems:
PROBLEM
CORRECTIVE ACTION
Noisy Pilot Flame
Locate pilot adjustment screw
on gas control valve. Flame
is decreased by turning
adjustment screw clockwise.
Pilot won’t ignite
Disconnect remote wires and
try to light pilot. If pilot now
works, remote connections are
faulty. Check wiring diagram
figure 49.
Main Burner won't light
1. Check wiring (see figure 49).
2. Check wall switch for proper
connection.