Page 8
HT34-PV Series Power Vent Gas Fireplace
Part No. XG0530 - 041510
Installation
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in
Figure 24
. Side wall clearances are 3".
Combustible surrounds may be installed with 3" clearance to the side
of the fireplace as shown in
Figure 25
.
Figure 25.
Combustible surrounds.
Figure 24.
Combustible mantles and facings.
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following:
If the surround of the fireplace is to be painted to match the room decor,
heat-resistant paint must be provided . Also, decorative facing must not
extend past the fireplace opening at all, because it will interfere with the
access to retainers for removal of glass door and access to the lower
compartment.
Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Warning:
When covering the upper metal portion of the fireplace, up to 6" (
as
shown,
Fig.24 & Fig.25
) with a non-combustible material Please Note:
The decorative facing materials may be subject to temperatures in excess
of 250° F. This should be considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discoloration or premature failure of T.V. and radio components.
Horizontal Run (in)
Facing Material
Header
Drywall/
Sheetrock
Installing The Horizontal &
Vertical Exterior Power Vent
A Power Vent is required for the
HT34-PV
rear or Top vent gas fire-
place
. There are four 4/7 Power Vent models available. These Power
Vents are required for Superior venting, safe operation & years of
trouble free operation.
The available Montigo Power Vent models are:
LDVPV47 (Linear, Interior In-line Power Vent,
document, XG0700)
.
EDVPV47 (External Power Vent Module,
document, XG0750)
.
EDVRSPV47 (Exterior
Vertical
Roof mount 4/7 stainless steel Power
Vent system,
document, XG1303)
EDVWSPV47 (Exterior
Horizontal
Wall mount 4/7 stainless steel Power
Vent system,
document, XG1302)
.
WARNING:
An inspection of the explosion relief flappers and door
MUST
be made prior to lighting the fireplace. A faulty seal
on the door gasket and/or explosion ports will result in
products of combustion leaking into the living space and
may result in carbon monoxide poisoning.