background image

Page 1

L-Series DF Gas Fireplace

Part No. XG0180

f i r e   f e a t u r e

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

If  you  cannot  reach  your  gas  supplier,  call  the  Fire 
Department.

C.

  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempt to repair may result in a fire or explosion.

D.

  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system, and 
any gas control which has been under water.

A. 

This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor.

 

What To Do If You Smell Gas:

Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone 
in your building.
Immediately call your gas supplier from a neighbour's 
phone. Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

Operation - Model L-Series DF

3.  Push in gas control knob slightly and turn  

  clockwise to 

"Off".  Do not force.

4.  Flip up the lower trim.

1.  Turn off remote switch.
2.  Flip down the lower trim.

1.

 

STOP!

 

 

Read the safety information above on this label.

2.

  Flip down the lower trims.

3.

  Push in gas control knob and turn clockwise 

  to "OFF."

4.

  Wait  five  (5)  minutes  to  clear  out  any  gas.  Smell  for  gas, 

including near the floor. If you then smell gas, 

STOP!

 Follow 

"B" in the safety information above on this label. If you don't 
smell gas, go to the next step.

5.

  Locate pilot burner 

(See illustration at right.)

 and follow steps 

below.

6.

  Turn  knob  on  gas  control  counter  clockwise   

    to 

"PILOT."

7.

  Push in gas control knob completely and hold. Light with Piezo 

Igniter button. Continue to hold the control knob in for about 
(1) minute after the pilot is lit. Release the knob and it will pop 
back up. Pilot should remain lit. If it goes out repeat steps 3 
through 8.

If  knob  does  not  pop  up  when  released.  Stop  and 
immediately  call  your  service  technician  or  gas 
supplier.
If the pilot will not stay lit after several 
tries,  turn  the  gas  control  knob  to 
"OFF" and call your service technician 
or gas supplier.

8.

  Push in gas control knob and turn counter-

clockwise  

  to "ON."

9.

  Flip up the lower trim.

10. 

Turn on remote switch to ignite fire.

Lighting  Instructions:

L-Series DF

with Continuous  Pilot

For Your Safety - READ BEFORE LIGHTING:

NOTE: 

Gas control knob cannot be turned from 

 

"PILOT" to "OFF" unless knob is pushed

 

 in slightly.  Do not force.

Summary of Contents for L38DF series

Page 1: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department For Your Safety Do not store or use gasolineorotherflammable vapors and liquids in the vicin...

Page 2: ...or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your lo...

Page 3: ...t be installed on a metal or wood panel extending the full width and depth of the appliance Top View Front View Side View Unprotected combustible walls which are perpendicular to the fireplace opening...

Page 4: ...C a manifold pressure of 3 5 W C Propane Gas requires a minimum inlet gas supply pressure of 11 W C a manifold pressure of 10 W C Provision must also be made for a 1 8 N P T plugged tapping and be ac...

Page 5: ...termination where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws Installing Heat Guards over Terminations Installing The Remote Switch The L Serie...

Page 6: ...d fireplace Figure 7b Flue collar installation for Top Vented fireplace Figure 8a Flue cap installation for Rear Vented fireplace Figure 8b Flue collar installation for Rear Vented fireplace L Series...

Page 7: ...acceptable installation Figure 9a L38DF Top Vent Venting Graph L42DF Example A Acceptable Installation If the vertical dimension from the hearth is 84 and the horizontal run to the wall flange of the...

Page 8: ...installation Thesolidsectionscanbeusedin variouscombinationstoobtainthedesiredventrun Thevent run must fall within the limits set by the venting graph Figure 12 Extended Installation using a combinati...

Page 9: ...wo offsets each offset has two 90 bends may be made and shall not exceed total length of 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 20 ve...

Page 10: ...ith 1 offset 1 offset two 90 bends Figure 18 Reducing Vertical Vent from 5 8 to 4 7 Reduced Vertical Installation It is possible to reduce vertical vent runs from 5 8 venting to 4 7 venting Reducedver...

Page 11: ...hield Heat Shield The heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects to the termination With the heat shield proper vent clear...

Page 12: ...tallation If the vertical dimension from the floor of the fireplace is 78 and the horizontal run to the wall flange of the vent termination is 108 this would not be an acceptable installation Figure 2...

Page 13: ...MTO 3F 3 Length PTO 3 3 Length PTO 3F 3 Length B Stucco Kits MSR Stucco Frame BSR 4 4 Brick Frame BSR 6 6 Brick Frame MOSR Stucco Can MSR Stucco Frame BSR 4 4 Brick Frame BSR 6 6 Brick Frame MOSR Stuc...

Page 14: ...cing materials may be subject to temperatures in excess of 250 F This should be considered when selecting facing materials We recommend careful consideration be given to the effects of elevated mantel...

Page 15: ...d with the same type or its equivalent Figure 27b Wiring schematic for optional fans Figure 27a Wiring for optional fans Removing and Installing the Door Removing the door The door is held in place by...

Page 16: ...ff Gas To Appliance Operation Model L Series DF 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim...

Page 17: ...try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1...

Page 18: ...ting Instructions To Turn Off Gas To Appliance 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 If the switch on the control module is set to Continuous Pilot Off t...

Page 19: ...ll a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operation Lighting Instructions See pages 16 17...

Page 20: ...r until the bubbling stops completely Figure 34 Pilot Burner Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adju...

Page 21: ...jected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce...

Page 22: ...t minimum in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for...

Page 23: ...Spare Parts L SeriesDF L38DF L42DF NG Gas Valve RGC1006 RGC1006 LP Gas Valve RGC1005 RGC1005 NG Pilot RPA020 RPA020 LP Pilot RPA021 RPA021 Burner NG RBL3801 RBL4201 Burner LPG RBH3802 RBL4202 ROR1151...

Page 24: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0180 033007...