Maintenance
Gas Control Valve
Troubleshooting
L-Series DF-I
Manifold Pressure
Test Connection
Pilot Adjustment Screw
Inlet
Pressure
Power
Generator
Wall Switch
Figure 33.
Sit Nova 820
gas valve
.
Pilot Burner Adjustment
1.
Locate Pilot Adjustment Screw.
(See figure 33.)
2.
Adjust pilot screw to provide properly sized flame as shown in
figure 34).
3.
After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
Figure 34.
Pilot Burner.
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
CORRECTIVE ACTION
Noisy Pilot Flame
Locate pilot adjustement screw on
gas control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram
figure
33.
Main burner will
1. Check wiring (
see figure 33
).
not light
2. Check wall switch for proper con-
nection.
L-Series DF
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.