background image

Page 21

L-Series DF Gas Fireplace

Part No. XG0180

f i r e   f e a t u r e

The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a 
ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve 
and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 
outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 
and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 
will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 
are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 
replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 
Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local 
building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 
expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 
or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 
with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 
lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.
The Companies Are Not Responsible For Work Done Without Written Consent
The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.
Dealers Have No Authority To Alter This Warranty
The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated 
above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 
possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without 
notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Warranty

Summary of Contents for L38DF series

Page 1: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department For Your Safety Do not store or use gasolineorotherflammable vapors and liquids in the vicin...

Page 2: ...or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your lo...

Page 3: ...t be installed on a metal or wood panel extending the full width and depth of the appliance Top View Front View Side View Unprotected combustible walls which are perpendicular to the fireplace opening...

Page 4: ...C a manifold pressure of 3 5 W C Propane Gas requires a minimum inlet gas supply pressure of 11 W C a manifold pressure of 10 W C Provision must also be made for a 1 8 N P T plugged tapping and be ac...

Page 5: ...termination where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws Installing Heat Guards over Terminations Installing The Remote Switch The L Serie...

Page 6: ...d fireplace Figure 7b Flue collar installation for Top Vented fireplace Figure 8a Flue cap installation for Rear Vented fireplace Figure 8b Flue collar installation for Rear Vented fireplace L Series...

Page 7: ...acceptable installation Figure 9a L38DF Top Vent Venting Graph L42DF Example A Acceptable Installation If the vertical dimension from the hearth is 84 and the horizontal run to the wall flange of the...

Page 8: ...installation Thesolidsectionscanbeusedin variouscombinationstoobtainthedesiredventrun Thevent run must fall within the limits set by the venting graph Figure 12 Extended Installation using a combinati...

Page 9: ...wo offsets each offset has two 90 bends may be made and shall not exceed total length of 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 20 ve...

Page 10: ...ith 1 offset 1 offset two 90 bends Figure 18 Reducing Vertical Vent from 5 8 to 4 7 Reduced Vertical Installation It is possible to reduce vertical vent runs from 5 8 venting to 4 7 venting Reducedver...

Page 11: ...hield Heat Shield The heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects to the termination With the heat shield proper vent clear...

Page 12: ...tallation If the vertical dimension from the floor of the fireplace is 78 and the horizontal run to the wall flange of the vent termination is 108 this would not be an acceptable installation Figure 2...

Page 13: ...MTO 3F 3 Length PTO 3 3 Length PTO 3F 3 Length B Stucco Kits MSR Stucco Frame BSR 4 4 Brick Frame BSR 6 6 Brick Frame MOSR Stucco Can MSR Stucco Frame BSR 4 4 Brick Frame BSR 6 6 Brick Frame MOSR Stuc...

Page 14: ...cing materials may be subject to temperatures in excess of 250 F This should be considered when selecting facing materials We recommend careful consideration be given to the effects of elevated mantel...

Page 15: ...d with the same type or its equivalent Figure 27b Wiring schematic for optional fans Figure 27a Wiring for optional fans Removing and Installing the Door Removing the door The door is held in place by...

Page 16: ...ff Gas To Appliance Operation Model L Series DF 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim...

Page 17: ...try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1...

Page 18: ...ting Instructions To Turn Off Gas To Appliance 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 If the switch on the control module is set to Continuous Pilot Off t...

Page 19: ...ll a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Operation Lighting Instructions See pages 16 17...

Page 20: ...r until the bubbling stops completely Figure 34 Pilot Burner Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adju...

Page 21: ...jected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce...

Page 22: ...t minimum in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for...

Page 23: ...Spare Parts L SeriesDF L38DF L42DF NG Gas Valve RGC1006 RGC1006 LP Gas Valve RGC1005 RGC1005 NG Pilot RPA020 RPA020 LP Pilot RPA021 RPA021 Burner NG RBL3801 RBL4201 Burner LPG RBH3802 RBL4202 ROR1151...

Page 24: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0180 033007...