Page 12
L38DF* Indoor Gas Fireplace
XG0180 - 053111
Installation
Figure 16.
Corner installation.
Figure 17.
Flex installation. (NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-
20 to suit, and attach it to the PEL-45. Slide the fireplace into position
and attach to the termination.
45° or less Corner Installation.
Use an PTO-3 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24"
compressed length) and a frame, if appropriate.
Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation.
The Kit includes a heat
shield, a PFL-12 (f/f) flexible pipe, and a termination with or without
a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
IMPORTANT:
Corner Installation is available for L38DF
Top Vent Units Only
. Ensure minimum
Vertical Venting Height of 36" is maintained
in corner installations.