Page 6
L38DF* Indoor Gas Fireplace
XG0180 - 053111
Installation
Section 2: Framing
1).
Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled fireplace is 37 3/4" wide, x 35 1/4"
high x 20 1/8" deep, see
Figure 2
.
NOTE:
When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed.
See
Figure 2
.
Figure 2.
Framing dimensions, (Straight wall & Corner
Installation).
Clearances
When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear
of the fireplace to a wall, or any combustible materials, and 9" clearance
from the top of the fireplace to the underside of any combustible shelf
materials.
For Top Vent applications, the minimum clearance is 2" from the rear of
the fireplace to a wall, or any combustible materials, and 17 1/2" to the
underside of any combustible shelf materials.
(Minimum 2" clearance must still be maintained around the vent
pipes.)
* When sheetrock is not used behind the
fireplace, framing depth 20 1/8" may be
reduced by 5/8".
Figure 5.
Non Combustible Framing for Top Vent or Rear
Vent, with alcove.
Note: Straight through the wall rear
vent available for Natural Gas only.
20 1/8”
37 3/4”
35 1/4”
75
0" clearance
to corners only
37 3/4
54 1/4”
Figure 4.
Combustible Framing for shelves over the fireplace,
Top vent.
Figure 3.
Combustible Framing for shelves over the fireplace,
Rear vent.
Note: Rear vent available for Natural Gas only.
MODEL
Top - Rear vent
*
Top - T
op vent
Back
Sides
Floor
Mantel
L38DF*
9"
17 1/2"
1"
1"
0"
4"
L38DF
9”
MODEL
Top - Rear Vent *
Top - Top Vent
Back
Sides
17
1 2
/
”2
Floor
Mantel
0”
1”
4”
MIN
84”
to
96”
Non-
combustible
header
12”
6”
door
opening
3”
Rear
Vent
Min 1”
Ceiling
Floor
Alcove
area over
Fireplace
Top
Vent
2” min.
18” max.
MIN
84”
to
96”
12”
6”
door
opening
3”
Rear
Vent
Cieling
Floor
Alcove
area over
Fireplace
Top Vent
N.G. & L.P.
18”
max.
1” min.
Non-combustible
header
Min 1”
35 1/4”
9”
29”
Combustible Header
Combustible Shelf
21 3/4”
12”
max.
REAR VENT
N.G ONLY
REAR VENT
N.G ONLY
1” min.
35”
MEL Short
90° elbow
35 1/4”
17 1/2”
Combustible Header
Combustible Shelf
1” min.
xx” Max.
46” Min.
12”
Max.
Flex or Rigid
Section
24 1/4”
Min.
21 3/4”
RHS8 Heat
Shield
PTO Termination
36” Min
46” Min.
Models Included
L38DFN
L38DFL
Models Included
L38DFN I
L38DFLI
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
A
C
B
42” NG
36” LP
36
35” NG & LP
RHS8 Heat
Shield
36” Min
46” Min.
PTO Termination
L38DF
9”
MODEL
Top - Rear Vent *
Top - Top Vent
Back
Sides
17
1 2
/
”2
Floor
Mantel
0”
1”
4”
MIN
84”
to
96”
Non-
combustible
header
12”
6”
door
opening
3”
Rear
Vent
Min 1”
Ceiling
Floor
Alcove
area over
Fireplace
Top
Vent
2” min.
18” max.
MIN
84”
to
96”
12”
6”
door
opening
3”
Rear
Vent
Cieling
Floor
Alcove
area over
Fireplace
Top Vent
N.G. & L.P.
18”
max.
1” min.
Non-combustible
header
Min 1”
35 1/4”
9”
29”
Combustible Header
Combustible Shelf
21 3/4”
12”
max.
REAR VENT
N.G ONLY
REAR VENT
N.G ONLY
1” min.
35”
MEL Short
90° elbow
35 1/4”
17 1/2”
Combustible Header
Combustible Shelf
1” min.
xx” Max.
46” Min.
12”
Max.
Flex or Rigid
Section
24 1/4”
Min.
21 3/4”
RHS8 Heat
Shield
PTO Termination
36” Min
46” Min.
Models Included
L38DFN
L38DFL
Models Included
L38DFN I
L38DFLI
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
A
C
B
42” NG
36” LP
36
35” NG & LP
RHS8 Heat
Shield
36” Min
46” Min.
PTO Termination
L38DF
9”
MODEL
Top - Rear Vent *
Top - Top Vent
Back
Sides
17
1 2
/
”2
Floor
Mantel
0”
1”
4”
MIN
84”
to
96”
Non-
combustible
header
12”
6”
door
opening
3”
Rear
Vent
Min 1”
Ceiling
Floor
Alcove
area over
Fireplace
Top
Vent
2” min.
18” max.
MIN
84”
to
96”
12”
6”
door
opening
3”
Rear
Vent
Cieling
Floor
Alcove
area over
Fireplace
Top Vent
N.G. & L.P.
18”
max.
1” min.
Non-combustible
header
Min 1”
35 1/4”
9”
29”
Combustible Header
Combustible Shelf
21 3/4”
12”
max.
REAR VENT
N.G ONLY
REAR VENT
N.G ONLY
1” min.
35”
MEL Short
90° elbow
35 1/4”
17 1/2”
Combustible Header
Combustible Shelf
1” min.
xx” Max.
46” Min.
12”
Max.
Flex or Rigid
Section
24 1/4”
Min.
21 3/4”
RHS8 Heat
Shield
PTO Termination
36” Min
46” Min.
Models Included
L38DFN
L38DFL
Models Included
L38DFN I
L38DFLI
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
A
C
B
42” NG
36” LP
36
35” NG & LP
RHS8 Heat
Shield
36” Min
46” Min.
PTO Termination