Page 26
L52DF* Indoor Gas Fireplace
XG0185 - 100511.1
Operation
To Turn Off Gas To Appliance:
1.
Turn off remote switch.
2.
Remove the lower Horizontal access panel.
3.
Turn the incoming gas control valve to "Off".
4.
Replace the lower Horizontal access panel.
Lighting Instructions:
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service technician.
Force or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.
A. This appliance is equipped with an ignition system that lights
the pilot burner automatically. Do not attempt to light the pilot
by hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn Incoming gas valve to the ON" position.
4. Wait 5 minutes to clear out any gas. If you smell gas,
STOP! Follow "B" in the safety information above on this
label. If you don't smell gas, go to the next step.
5. Turn wall switch "ON".
6. If the Fireplace does not light, the System will cycle through
two trials, (one minute audible clicking, thirty seconds of
silence, and then another one minute of audible clicking).
7. After completion of the information in the Troubleshooting
section, Repeat step 5.
8. If the system will not function correctly, follow the instruc-
tions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
EV1 (Pilot
burner)
EV2 (Main
burner)
Pilot Adjust Screw
Lockout Reset Key
Diagnostic Terminal
Power
Command (Wall
switch)
Pilot Sensor
Igniter
Ground
EV1 (Pilot burner)
EV2 (Main burner)
Gas "Out"
Gas "In"
Incoming Gas
Line, Shut-off
Valve
To fireplace Main
burner
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
SIT Proflame Electronic Ignition