Page 28
L52DF* Indoor Gas Fireplace
XG0185 - 100511.1
Maintenance
Troubleshooting
SIT Nova 820:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTIOn
Noisy Pilot Flame
Locate pilot adjustment screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram
figure 26
.
Main burner will not ignite
1. Check wiring (see
figure 26
).
2. Check wall switch for proper
connection.
SIT Proflame System:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTIOn
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main burner will not light.
- Check the wiring on the valve as per
diagram
Figure 18
Fan not working
- Make sure the fan speed control is on.
- 10 minute delay to turn on.
If your fireplace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualified Technician.
All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.