Page 6
L52DF* Indoor Gas Fireplace
XG0185 - 100511.1
Installation
Section 2: Framing
Figure 2.
Framing dimensions.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8".
0" clearance
to corners only
96 1/2”
52”
68 1/4”
Figure 3.
Minimum Corner framing dimensions
Figure 4a.
Framing for shelves over the fireplace, Top Vent
(Combustible materials).
Figure 5.
Non Combustible Framing for Top Vent or Rear Vent with
Alcove Above Fireplace.
Frame in the enclosure for the unit with framing materials. The framed
opening for the assembled fireplace is 52" wide, x 39½" high x 25⅜"
deep, see
Figure 2
.
nOTE:
When constructing the framed opening, please ensure there is
access to install the gas line when the unit is installed.
See
Figure 21
.
MIN
84”
Header
3”
MIN
1”
Floor
Alcove
area over
Fireplace
Top
Vent
Non-Combustible
Materials Only
Ceiling
Figure 4.
Framing for shelves over the fireplace, Rear Vent
(Combustible materials).
Top Vent
elbow
Shelf
40”
39 1/2”
Header
24”
3” Min
39 1/2”
10”
Framing / Header,
supplied shield
shelf
Rear Vent
1” Min
1” Min
52”
39 1/2”