Page 8
L52DF* Indoor Gas Fireplace
XG0185 - 100511.1
Installation
Figure 8.
Combustible Framing Side Heat Shield
L52FS01x2
, (two 2-pcs).
Framing the Heat Shield
Included with the
L52DF*
Gas fireplace, is a framing heat shield Kit. This
Kit is fabricated from galvanized steel and arrives with three (3) pieces,
as shown below. The shields protect all adjacent combustible materials,
mantels and mouldings from excessive heat radiated by the fireplace.
nOTE:
The shields must be installed as shown in
Figures 8
-
8b.
Step 1
. Fasten the two Side shield's (
L52FS01x2
) first, and ensure they
are fastened in place as shown. These are installed with the Wide flanges
facing the center of the fireplace opening, and the shallow flange toward
inside of room. These are also fastened with nails or screws, flush with
framing as shown in
Figure 8
and
Inset.
Figure 8a.
Combustible Framing Top Heat Shield
L52FS02x1
, (one 1-pc).
Figure 8b.
Combustible Framing Heat Shield, completed.
Step 2
. Next, fasten the Top shield (
L52FS02x1
), with the Wide flange
face up, and the shallow flange toward inside of room,
Figure 8a
.
Step 3.
Nail or screw the top shield in place flush with framing, as shown
in
figure 8b.
fireplace
framing
fasteners,
3-per. side
Both Side
shields typical
flush with
framing
INSET
Section
fireplace
Top shield
INSET
Section
flush with
framing
fireplace
framing
fasteners,
3-pcs.
INSET
Section
flush with
framing
1/2