L52DF*ST Indoor Gas Fireplace
Page 16
XG0811 - 151126
Models Included
L52DF-STN-F
L52DF-STL-F
Figure 12. Wiring Diagram for the SIT Proflame 2 Electronic Ignition
Manifold Pressure
Test Connection
Wall Switch
Power
Generator
Pilot Adjustment Screw
Inlet Pressure
'Hi-Lo' Adjustment Knob
Gas Control Knob (Shown in “Pilot” position)
Figure 13. Wiring Diagram for SIT Nova 820 gas and pilot.
Models Included
L52DF-STN
L52DF-STL
Section 4: Wiring
Installing the remote On/Off Wall Switch
The L52DFST* gas valve may be connected to a wall switch. Do
NOT connect any external power to the remote switch. The valve
will generate its own power on a millivolt circuit or will draw its
power from an AC Connection inside the fireplace, depending on
the model of the unit. Use only low voltage wire, and DO NOT
connect any external power to the remote switch.
Refer to Figure 12 or 13 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fire
-
place.
NOTE:
If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
1.5V AA type
1.5V AA type
1.5V AA type
1.5V AA type
BLACK
WHITE
GREEN
To PPO
SPARK
SENSOR
RED
BLACK
BATTERY
PACK
TO ON/OFF
WALL SWITCH
YELLOW/GREEN
ORANGE
GREEN
6
10
4
6
3
4
OPTIONAL CPI/IPI SWITCH
BLUE
WHITE
X1
X5
X4
X3
X2
LED Lights
LED1 - Red LED
LED2 Amber LED
3.15A FUSE
SW1
BLUE
RED
OPTIONAL
X10
X11
X12
X13
Installation
jumper