Section 8: Installing & Removing the Door
Removing the door:
The L52DF-ST* doors are removed in a few simple steps. Follow
these instructions below to remove the Horizontal access panel,
unlatch the door buckles and, remove the door. Replace in
reverse order.
Figure 18a. Locate the door buckles. Both sides typical.
Figure 18. Removing and installing the Horizontal Access Panel
Locate the Door Buckles.
Step 2:
Step 1:
Remove the Horizontal cover
by placing fingers in both
finger holes, then pushing
away from you and lifting
out. Place it aside during
maintenance or cleaning.
Install in reverse order.
2
Step 5:
Ensure the tool is
firmly in the lower end
of the slot, (as shown),
Then pull toward you
(Caution: hold the tool
securely).
3
Step 6:
Pull hard if necessary to
release the spring ten-
sion. (Caution: The latch
springs back with force,
hold the tool securely).
4
Step 7:
Remove the tool from
the latch slot. Ensure
the latches are hanging
freely, the hook end is
released from the bottom
of the door. (Repeat all
4-steps for the remaining
latches).
Figure 18d.
Figure 18e.
Figure 18f.
Door Latch Hook
Door Latch Slot
Hand-hold
Figure 18b. Door buckle Tool
1
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under
door frame. (as shown)
Figure 18c.
Finger Holes
Installed Gas
Valve Cover
Step 3:
Locate Door Buckle Tool.
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.
Installation