L52DF*ST Indoor Gas Fireplace
Page 26
XG0811 - 151126
Initializing the System for the first time
1. Set master override switch to off position.
2. Install four (4) AA batteries into the battery holder.
3. Install three (3) AAA batteries in the back of the remote con-
trol.
Note the polarity of batteries and install them as indicated by the
silk screen (+/-) on the holder.
4. Connect AC Power (115 volts, 60 Hz) to fireplace.
Operating the System for the first time
5. Press SW1 button on the control module. The control mod-
ule will beep three (3) times and an amber LED is illuminated
to indicate that the IFC is ready to synchronize with a remote
control within 10 sec. Push the ON button. The control module
will "beep" four (4) times to indicate transmitter's command is
accepted.
The System is now initialized.
Temperature indication Display
With the system in the "Off" position, press the Thermostat Key
and the Mode Key at the same time. Look at the LCD screen on
the Remote Control to verify that a C or F is visible to the right of
the Room Temperature display.
Turn On the Fireplace
With the system Off, turn the master override switch to on
and press the On/Off Key on the Remote Control. The Remote
Control display will show some other active Icons on the screen.
At the same time the Control Module will activate the fireplace. A
single "beep" from the Control Module will confirm reception of
the command.
Turn Off the Fireplace
With the system On, press the On/Off Key on the Remote Con-
trol. The Remote Control LCD display will only show the room
temperature. At the same time the Control Module will turn off
the fireplace. A single "beep" from the Receiver confirms recep
-
tion of the command.
Battery operated device.
Read the battery instructions before installing them
.
WARNING
into the system. Do not expose any battery, or its holder, or a device in which
batteries are installed, to a working temperature greater than 54°C / 129°F.
Figure 20c.
Remote Control Battery Compartment
Figure 20d.
R
emote Control display in Fahrenheit & Celsius.
Figure 20e.
Remote Control Display
Operation