Hi-Lo' Adjustment on the M38ODV-ST gas valve.
Burner Adjustment
The M38ODV-ST is equipped with an adjustable burner, allowing you
to raise or lower the flames. To adjust the flames, locate the black knob
marked 'Hi-Lo', in the centre of the gas control valve (See Figure 15).
The front burners are not adjustable.
To raise the flame height, turn the black knob (located behind the
lower trim)
counterclockwise
.
To lower the flame height, turn
clockwise
.