background image

Page 10

MD38-BV  Homefire

Maintenance

WARNING:

Do not attempt to clean glass when hot.

Do not clean glass with abrasive materials as any glass
etching may cause premature glass failure.

CAUTIONS

n

Fireplace gas control must be in the “OFF” position and pilot
and main burners extinguished when cleaning appliance with
a vacuum.

n

Doors and logs can get very hot. Handle only when cool.

General

n

Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 26.

n

For 

Natural Gas

 this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

n

For 

Propane Gas 

this appliance requires a minimum inlet

pressure of  11" W.C. and a manifold pressure of 10" W.C.

n

Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
liquids.

n

Do not use this appliance if 

any part has been under water

.

Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.

Operation

Lighting Instructions

See pages 8 and 9.

Burner Adjustment

The  MD38-BV  fireplace  is  equipped  with  an  adjustable  burner,
allowing  you  to  raise  or  lower  the  flames.  Operating  the  control
knob  as  described  below  will  adjust  both  the  main  burner  and  the
ember  burner.

n

To  raise  the  flame  height,  turn  the  black  knob  (located  behind
the  lower  trim) 

counterclockwise

.

n

To  lower  the  flame  height,  turn 

clockwise

.

Gas Control Knob
(Shown in "Pilot" postion.)

'Hi-Lo' Adjustment Knob

Figure 11.

'Hi-Lo' Adjustment on the MD38-BV's gas valve.

Cleaning

When the fireplace is first activated, there may be some smoking and
a visible film may be left on the glass. This is a normal condition, and
is the result of burning of protective coatings on new metal.

n

Glass must be cleaned periodically to remove any film (which is a
normal biproduct of combustion) which may be visible. Film can
easily be removed by removing the door, as shown on page 7.
Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.

n

Silicone seals on inner door during initial firing will "off gas",
leaving a visual deposit of a white substance on combustion
chamber walls. This can easily be removed using normal
household products.

n

Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.

n

Logs may be cleaned periodically with a vacuum to remove soot
or other contaminates.

Summary of Contents for MD38-BV

Page 1: ...or s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier For Your Safety Do not store or use gasoline or other...

Page 2: ...repairs should be done by aqualifiedcontractor Installations in Canada must conform to the current CAN CGA B 149 1 and 2 Gas Installation Code and local regulations If the optional air circulatingfankitisinstalled itmustbeelectricallygroundedin accordance with CSA C22 1 Canadian Electrical Code Part 1 and or LocalCodes Installations in the USA must conform to local codes or in the absense of local...

Page 3: ...he B Vent manufacturer Clearances The MD38 BV clearances to combustible materials are Top 16 Back 0 Side 1 1 2 Floor 0 Mantle 9 B Vent See Notes Clearance from the top of the fireplace to a combustible ceiling within the fireplace enclosure Refer to page 5 This model requires 2 clearance around the B Vent within the fireplace enclosure Past the enclosure use standard clearance as specified by the ...

Page 4: ...to a wall switch The valve generates its own power on a millivolt circuit Use only low voltage wire and DO NOT connect any external power to it Refer to Figure 26 for wiring requirements Note The switch location must not exceed 30 from the fireplace Figure 4 Gas line access 2 1 2 Gasline access 6 x 2 1 2 1 The appliance and its individual shutoff valve must be disconnected from the gas supply pipi...

Page 5: ...f energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temperature and walls above fireplace may be hot to touch We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or ...

Page 6: ... schematic for optional fan kit 115 1 60 Supply G L1 L2 Embers Log D Log E Log A Installing the Log Set Installing the Logs The MD38 BV is supplied with five ceramic fibre logs Unpack the logs and handle them very carefully 1 Remove the door cover and the glass door 2 Place the Back log onto the back log rest as shown below in figure 8a Theloghasliponthebottomwhichfitsintotheslotonthelogrest 4 Pla...

Page 7: ...he steps above Figure 9 MD38 BV insert INSET 1 Tab INSET 2 Mounting Bracket Fresh Air Flex 4 dia High temp silicone seal Venting Plate Front Slot Removing and Installing the Door Removing the door surround The door surround is held in place by two metal clips at the top and one magnet on each side To remove the surround pull the bottom outwards and lift upwards until the slots A are clear of tabs ...

Page 8: ...del MD38 BV 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up lower Trim 1 Turn off remote switch 2 Flip down lower trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you then smell gas STOP Fol...

Page 9: ...any appliance n Do not touch any electrical switch do not use any phone in your building n Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower trim 3 Turn the switch on the gas control to Off 4 Flip up lower trim 1 STOP Read the safety information above on this label 2 Flip down lower trims 3 Turn switch on t...

Page 10: ... Lighting Instructions See pages 8 and 9 Burner Adjustment The MD38 BV fireplace is equipped with an adjustable burner allowing you to raise or lower the flames Operating the control knob as described below will adjust both the main burner and the ember burner n To raise the flame height turn the black knob located behind the lower trim counterclockwise n To lower the flame height turn clockwise G...

Page 11: ...former Line Volt Supply Replace SV9500 SV9600 Save old Igniter Flame Rod Assembly for service INSET HSI Terminals CHECK Line voltage power Low voltage transformer Limit Controller Thermostat Wiring Air proving switch on combustion air blower system Vent damper if used is open and end switch made MD38 BV I Gas Control Valve Figure 12 Sit Nova 820 gas valve Pilot Burner Adjustment 1 Locate Pilot Adj...

Page 12: ... will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other warranty expressed or im...

Page 13: ...Options and Accessories 1 Add onBayWindow 2 Hand HeldRemoteControl 3 VariableSpeedBlowerKit 4 4 Fan Kit 5 4 PiecePictureFrameSurround PFS 6 3 PiecePictureFrameSurround PFO 7 DoorCover Square DF0 8 DoorCover Arched DFA 9 Horizontal Trim Kits Black Brass Nickel 10 ReplacementLogset ...

Page 14: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0309 Rev 2 09 00 ...

Reviews: