Page 24
P38DF* Indoor Gas Fireplace
XG0193 - 053111.1
Maintenance
Troubleshooting:
SIT Proflame:
The following is a troubleshooting chart of possible problems:
PROBLEM
SOLUTIOn
Pilot won't ignite or spark. - Check the on the batteries on the
remote or the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under
the valve
Main burner will not light.
- Check the wiring on the valve as per
diagram
One or more light bulbs are
not working
- Contact the local dealer for repairs
or service
Fan not working
- Make sure the fan speed control is on.
- 10 minute delay to turn on.
Replacement Parts List
P38DF*
ng gas Valve with Stepper Motor
RGC3033
LP gas Valve with Stepper Motor
RGC3034
ng Pilot Assembly
RPA033
LP Pilot Assembly
RPA034
Igniter Probe Assembly
RGC3052
Flame Sensor Rod Assembly
RGC3053
Burner
Contact Dealer
ng Burner Orfice
R0R1150
LP Burner Orfice
R0R1157
Pilot Tubing - 18"
RPTA03
Control Module
RGC3035
Wiring Harness
RGC3041
DC Adapter
RGC3043
Door Assembly
RDTP52
If your fireplace still does not operate correctly, consult your local Montigo dealer.
All service and repairs should be performed by a qualified Technician.
All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer.
Figure 27
. Remove the up-lighting glass from the burner tray.
Replacing Light Bulbs
The
P38DF*
light bulbs can be replaced in a few simple steps. Follow
the directions for removing the door on
page 20.
Once the door has
successfully been removed, proceed with
figures 27 - 27b
.
Figure 27a
. Wear gloves when handling light bulbs. To remove
a light bulb, pull connecting wire away from bulb and pull
light bulb up. Replace with new light bulb.
Figure 27b
. Rotate newly replaced bulbs in a full circle. Place
glass cover back in the burner tray.