Page 6
P38DF* Indoor Gas Fireplace
XG0193 - 103111.1
Installation
Section 2: Framing
1).
Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled fireplace is 37 3/4" wide, x 41 1/4"
high x 20 1/8" deep, see
Figure 2
.
nOTE:
When constructing the framed opening, please ensure there is
access to install the gas line when the unit is installed. See
Figure 21
.
Figure 2.
Framing dimensions, (Straight wall & Corner
Installation).
Figure 5.
Non Combustible Framing for Top Vent or Rear
Vent, with alcove.
Note: Straight through the wall rear
vent available for Natural Gas only.
Figure 4.
Combustible Framing for shelves over the fireplace,
Top vent.
Figure 3.
Combustible Framing for shelves over the fireplace,
Rear vent.
Note: Rear vent available for Natural Gas only.
78 1/2
”
0" clearance
to corners
37 3/4
55 1/2”
MIN
96”
12”
door
opening
3”
Rear
Vent
Ceiling
Floor
Alcove
area over
Fireplace,
Top Vent
N.G. & L.P.
12”
max.
Non-combustible
header
Min 1”
REAR VENT
N.G ONLY
Non-Combustible
Materials Only
* When steetrock is not used behind the
fireplace, framing depth 20 1/8” may be
reduced by 5/8”
20 1/8
”
37 3/4”
411/ 4”
41 1/4”
9”
33 3/4”
Combustible Header
Combustible Shelf
26 3/8”
12”
max.
REAR VENT
N.G ONLY
Non Combustible
Stud 1/2” Above Top
RHS102
39”
MEL Short
90° elbow
49 3/4”
17 1/2”
Combustible Header
Combustible Shelf
RHS102
Non Combustible
Stud 1/2” Above Top