Figure 15.
Corner (Rigid) installation. (NG Models Only)
Figure 15a.
Corner (Flex) installation. (NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-
20 to suit, and attach it to the PEL-45. Slide the fireplace into position
and attach to the termination.
45° or less Corner Installation.
Use an PTO-4 termination and an PFL-1 or PFL-2 (12" or 24"
compressed length) and a frame, if appropriate.
Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation.
The Kit includes a heat
shield, a PFL-18 (f/f) flexible pipe, and a termination with or without
a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
IMPORTANT:
Corner Installation is available for P42DF
Top Vent Units Only
. Ensure minimum
Vertical Venting Height of 48" is maintained
in corner installations.
Note:
Images are shown without screens for clarity purposes. However,
your fireplace should not be operated without proper installation of
screens.
Page 15
P42DF* Indoor Gas Fireplace
XG0195 -150204.2
Installation