Page 15
P52DF* Indoor Gas Fireplace
XG0196 - 150204.3
Installation
Figure 13.
Corner installation.
Figure 13a.
Flex installation.
45° Corner Installation.
Attach an REL-45 (45° elbow) directly onto the flue collar.
Cut the RXT-20 to suit, and attach it to the REL-45. Slide
the fireplace into position and attach to the termination.
45° or less Corner Installation.
Use an RTO-4 termination and an RFL-4 (48" compressed
length) and a frame, if appropriate.
Flex may be turned
to obtain desired degree of angle required but must not
exceed 45°.
Note: Through the wall venting kits are also available
for both the Straight and the Corner Installation.
The
Kit includes a RHS 104 heat shield, a RFL-2(f/f) flexible
pipe, and a termination with or without a mounting frame.
Flue Collar
REXT - 1
REL - 90 Elbow
REL - 45 Elbow
RXT 20
104
RTO-4F
RFL4
RTO-4F
104
Note: For corner installation you need a minimum 56" from hearth to centre of pipe. Framing must be done as
described in Figure 2 on page 6.
Note:
Images are shown without screens for clarity
purposes. However, your fireplace should not be operated
without proper installation of screens.