Page 29
P52DF* Indoor Gas Fireplace
XG0196 - 150204.3
Maintenance
Figure 27
. Remove the up-lighting glass from the burner tray.
The
P52DF*
light bulbs can be replaced in a few simple
steps. Follow the directions for removing the door on
page
20.
Once the door has successfully been removed, proceed
with
figures 27 - 27b
.
Figure 27a
. Wear gloves when handling light bulbs. To
remove a light bulb, pull connecting wire away from bulb
and pull light bulb up. Replace with new light bulb.
Figure 27b
. Rotate newly replaced bulbs in a full circle.
Place glass cover back in the burner tray.
SIT Proflame 2:
The following is a troubleshooting chart of possible problems:
If your fireplace still does not operate correctly, consult
your local Montigo dealer.
All service and repairs should be performed by a
qualified Technician.
All spare parts, optional fans, and optional trim finishes
are available from your local Montigo dealer.
PROBLEM
SOLUTION
Pilot Igniter won't
spark
1. Check the MAIN ON-OFF
switch (typically located below
the valve cover) and turn ON
2. Ensure main power is ON
or new batteries are installed in
the remote control and backup
battery pack (if available).
3. Check the 3.15A fuse in
the control box and replace if
necessary
Pilot Igniter sparking,
but Pilot burner will
not light
1. Verify the Inlet and Manifold
Gas Pressure are within
acceptable limits
2. Check all connections to gas
valve
3. Check connection to stepper
motor (if available)
Pilot lights , but Main
burner will not Light
1. Check and verify all wiring
connections as per the wiring
diagram.
2 . Verify the inlet and Manifold
Pressure are within acceptable
limits
Pilot lights , but Main
burner will not Light
and igniter continues
to spark
1. Check the Pilot Flame Sensor
Rod and clean with steel wool
or similar.
2 . Check the Pilot hood and
clean with steel wool if dirty.
3. Adjust pilot flame using the
pilot adjustment screw if the pilot
flame is too long or too short
(Flame should fully engulf the
sensor rod and must be stable).
4. Check and make sure the
ground wire from the pilot is
connected to the fireplace body.
Fans not working
1. Ensure main power is ON
(fireplace may be operating on
back up batteries).
2. Check the 3.15A fuse in
the control box and replace if
necessary
One or more light bulbs
are not working
- Contact the local dealer for
repairs or service
Replacing Light Bulbs
Troubleshooting: