Page 1
XG0204 04/05
Panorama Direct Vented Fireplace
Maintenance
Troubleshooting
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts, optional fans (see optional fan instruction guide), and
optional trim finishes are available from Canadian Heating Products
Inc. or your local dealer.
M38DV-
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
CORRECTIVE ACTION
Noisy Pilot Flame
Locate pilot adjustment screw on the
front of the gas control valve. Flame
is decreased by turning adjustment
screw clockwise.
Pilot won’t ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram
figure
19.
Main burner will
1. Check wiring
(see figure 19)
not light
2. Check wall switch for proper con-
nection.
3. Check pilot burner. If extinguished:
a. Allow fireplace to cool, then try to
relight.
b. If condition persists, call a qualified
service person.
M38DV-PRC