background image

Installation

Page 2

XT0016 - 092214

General Information

This blower kit is for installation with the models listed above.

KIT #

Contents

RX200NG

Control Module, Remote Control, Stepper Motor-NG,

Manual Override switch with harness and bracket,

backup battery pack, Proflame 2 operations manual,

hardware and batteries.

RX200LP

Control Module, Remote Control, Stepper Motor-LP,

Manual Override switch with harness and bracket,

backup battery pack, Proflame 2 operations manual,

hardware and batteries.

Before You Begin

Ensure that the power supply has been turned off at the breaker or 

fuse before beginning the installation. 
Shut off the gas supply at the shut-off valve, and ensure that the main 

burner and pilot light have been turned off and the fireplace has been 

cooled off for at least two hours before installation.

General Information

This upgrade kit contains the necessary components for field up-
grade of an approved Montigo fireplace from Proflame 2 basic control 
system to Full Load with remote.
The installation of this unit must also conform with local codes or, in 
the absence of local codes, with the 

American

 National Fuel Gas 

Code, ANSI Z223.1, or the 

Canadian

 Installation Code, CAN / CGA 

B149.

Tool Required

T20 Torx bit
Impact gun / Drill
1/4 " Nut driver bit

WARNING!

This upgrade kit shall be installed by a qualified service 

agency in accordance with the manufacturer's instructions 

and all applicable codes and requirements of the authority 

having jurisdiction. If the information in these instructions 

are not followed exactly, a fire, explosion or production of 

carbon monoxide may result causing property damage, 

personal injury or loss of life. The qualified service agency 

is responsible for the proper installation of this kit. The 

installation is not proper and complete until the operation 

of the converted appliance is checked as specified in the 

manufacturer's instructions supplied with this kit.

Note

Upon successful installation of this upgrade kit, the follow-

ing features are available for the user:
1.  Thermostatic and smart thermostatic control of the 

fireplace

2.  Main burner flame modulation (6 levels)
3.  Choice of Standing or Intermittent pilot (CPI switch 

required / not supplied)

4.  Comfort fan speed modulation (Remote Fan Kit 

RFK3002R or RFK3004R required)

5.  Battery backup for the main burner during power out-

age

Note: 

 You may remove the front cover (

See Figure 2

), or the 

burner assembly to access the control module and wiring. If 
removed, please ensure it is re-installed properly and all gas 
connections are leak tested.

Remote Control

Control Module

Battery Pack

Manual override 

switch with harness 

and bracket

Stepper 

Motor-NG 

or LP

Proflame 2 Operations 

Manual

Figure 1 

Contents of Proflame 2 Upgrade Kit

Hardware and 

batteries

Figure 2 

Fireplace front cover

Table of Contents
A. Disconnect Control Module and Harness: 

3

B. Stepper Motor Installation: 

4

C. Control Module Installation: 

5

D. Main ON/OFF Switch Installation: 

6

E. Battery Holder Installation: 

7

F. Operation with Backup Battery: 

7

G. Operation with MAIN Power: 

7

Summary of Contents for Proflame 2 Upgrade Kit RX 200 LP

Page 1: ... Ignition IPI B38DR 2 F B38 Rear Vent Electronic Ignition IPI C US Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any applian...

Page 2: ...uirements of the authority having jurisdiction If the information in these instructions are not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appli...

Page 3: ...nd Sensor Wire from connec tors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 5 X5 plug of control module Figure 6 X1 p...

Page 4: ...s shown 4 Manually thread the two supplied mounting screws into the valve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 11 G Figure 7 Replace Hi Lo knob on valve Figure 8 Stepper Motor LP 3 Position the stepper motor on the gas control valve as shown in Figure 11 E...

Page 5: ...nnect the Power Plug to X1 Figure 14 New Control Module 3 Connect the Spark and sensor wires to X2 and X3 4 Connect the Manual ON OFF switch to X4 5 Connect the Valve Harness to X5 6 Connect the Stepper motor harness to X6 7 Attach the Control module to the bottom of the firebox using the velcro strips supplied Figure 15 X1 plug on control module Figure 16 X2 X6 plugs on control module ...

Page 6: ...crews supplied attach the bracket See Figure 18 3 Feed the switch and the wires through the slot in the bracket as shown and install the switch to the bracket See Figure 20 4 Secure the wires to the floor of the fireplace using the supplied cable tie and cable tie mounts 5 Attach the Main ON OFF sticker supplied to the switch bracket Figure 18 Attach switch bracket to front of fireplace Figure 19 ...

Page 7: ...Control Module Power cord to the PPO box See Figure 3 3 Turn the fireplace ON using the remote control and confirm operation with main power ON Note You may re install the backup batteries to the battery holder at this point to ensure that fireplace is operational during power outage It is recommended to check and replace the backup batteries at least once a year More frequent battery replacement ...

Page 8: ...XT0016 092214 Proflame 2 Upgrade Kit RX 200 NG LP ...

Reviews: