background image

Installation

Page 6

XT0016 - 092214

Figure 17

 Attach switch bracket to front of fireplace

D. Main ON/OFF Switch Installation:

1.  Position the Main/off Switch bracket on the right leg of the 

firebox as shown in 

Figure 17 and Figure 18.

2.  Using the two selftapping screws supplied attach the bracket. 

See 

Figure 18.

3.  Feed the switch and the wires through the slot in the bracket as 

shown and install the switch to the bracket. See 

Figure 20

.

4.  Secure the wires to the floor of the fireplace using the supplied 

cable tie and cable tie mounts.

5.  Attach the "Main ON/OFF" sticker supplied to the switch bracket.

Figure 18

 Attach switch bracket to front of fireplace

Figure 19

 Attach switch to bracket.

Figure 20

 Attach switch to bracket.

Summary of Contents for Proflame 2 Upgrade Kit RX 200 LP

Page 1: ... Ignition IPI B38DR 2 F B38 Rear Vent Electronic Ignition IPI C US Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any applian...

Page 2: ...uirements of the authority having jurisdiction If the information in these instructions are not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appli...

Page 3: ...nd Sensor Wire from connec tors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 5 X5 plug of control module Figure 6 X1 p...

Page 4: ...s shown 4 Manually thread the two supplied mounting screws into the valve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 11 G Figure 7 Replace Hi Lo knob on valve Figure 8 Stepper Motor LP 3 Position the stepper motor on the gas control valve as shown in Figure 11 E...

Page 5: ...nnect the Power Plug to X1 Figure 14 New Control Module 3 Connect the Spark and sensor wires to X2 and X3 4 Connect the Manual ON OFF switch to X4 5 Connect the Valve Harness to X5 6 Connect the Stepper motor harness to X6 7 Attach the Control module to the bottom of the firebox using the velcro strips supplied Figure 15 X1 plug on control module Figure 16 X2 X6 plugs on control module ...

Page 6: ...crews supplied attach the bracket See Figure 18 3 Feed the switch and the wires through the slot in the bracket as shown and install the switch to the bracket See Figure 20 4 Secure the wires to the floor of the fireplace using the supplied cable tie and cable tie mounts 5 Attach the Main ON OFF sticker supplied to the switch bracket Figure 18 Attach switch bracket to front of fireplace Figure 19 ...

Page 7: ...Control Module Power cord to the PPO box See Figure 3 3 Turn the fireplace ON using the remote control and confirm operation with main power ON Note You may re install the backup batteries to the battery holder at this point to ensure that fireplace is operational during power outage It is recommended to check and replace the backup batteries at least once a year More frequent battery replacement ...

Page 8: ...XT0016 092214 Proflame 2 Upgrade Kit RX 200 NG LP ...

Reviews: