background image

Installation

Page 7

XT0016 - 092214

F. Operation with Backup Battery:

1.  Install the four supplied AA batteries to the battery holder.

CAUTION:

  Please note battery orientation while installing them. 

Incorrect orientation may damage battery, cause fire hazard and the 
fireplace may not function properly.

2.  Follow the instructions on the 

"Proflame2 Operation and Main

-

tenance Manual- XG0677" 

to install batteries on the remote 

control.

3.  Turn the gas supply ON.
4.  Program the remote control to the control module 

(see "Pro-

flame2 Operation and Maintenance Manual- XG0677")

.

5.  Check the stepper motor for gas leaks and ensure no leak.
6.  Turn the fireplace ON and modulate the flame using the remote 

control and ensure proper operation 

(see "Proflame 2 Opera

-

tion and Maintenance Manual XG0677")

.

G. Operation with MAIN Power:

1.  Remove the four batteries from the battery holder
2.  Plug the Control Module Power cord to the PPO box. See 

Figure 3

.

3.  Turn the fireplace ON using the remote control and confirm 

operation with main power ON. 

Note:  

You may re-install the backup batteries to the battery holder at 

this point to ensure that fireplace is operational during power outage. 
It is recommended to check and replace the backup batteries at least 
once a year. More frequent battery replacement may be required in 
case of extended operation on backup batteries.

E. Battery Holder Installation:

1.  Secure the battery holder to the fireplace floor using the supplied 

velcro strips. See 

Figure 21

.  

Note:  

The velcro strips act as an electrical isolation, do not attach 

the battery holder to any metal part without using the velcro strips, or 
the control module will be damaged.
2.  Connect the red and black wires from the battery holder to the 

red and black wires from the valve harness. See 

Figure 22.

Figure 21 

Battery holder

Figure 22 

Battery holder wires

Blue Back lit LCD display

On/Off Key

Thermostat Key

Up/Down Arrow Key

Mode Key

Figure 23 

Proflame Remote Control

Summary of Contents for Proflame 2 Upgrade Kit RX 200 LP

Page 1: ... Ignition IPI B38DR 2 F B38 Rear Vent Electronic Ignition IPI C US Warning If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any applian...

Page 2: ...uirements of the authority having jurisdiction If the information in these instructions are not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appli...

Page 3: ...nd Sensor Wire from connec tors X2 and X3 of the control module 3 Disconnect the wall switch harness from X4 Control Module and discard 4 Remove the Valve Harness from X5 of the control module 5 Remove the connector from X1 of the control module 6 Remove the control module from firebox compartment and discard Note module is attached by velcro strips Figure 5 X5 plug of control module Figure 6 X1 p...

Page 4: ...s shown 4 Manually thread the two supplied mounting screws into the valve body Use a torque screw driver with Torx T20 bit to tighten the two screws to a torque setting of of 25 lb in 5 5 Install the enclosed identification label to the valve body Figure 11 G Figure 7 Replace Hi Lo knob on valve Figure 8 Stepper Motor LP 3 Position the stepper motor on the gas control valve as shown in Figure 11 E...

Page 5: ...nnect the Power Plug to X1 Figure 14 New Control Module 3 Connect the Spark and sensor wires to X2 and X3 4 Connect the Manual ON OFF switch to X4 5 Connect the Valve Harness to X5 6 Connect the Stepper motor harness to X6 7 Attach the Control module to the bottom of the firebox using the velcro strips supplied Figure 15 X1 plug on control module Figure 16 X2 X6 plugs on control module ...

Page 6: ...crews supplied attach the bracket See Figure 18 3 Feed the switch and the wires through the slot in the bracket as shown and install the switch to the bracket See Figure 20 4 Secure the wires to the floor of the fireplace using the supplied cable tie and cable tie mounts 5 Attach the Main ON OFF sticker supplied to the switch bracket Figure 18 Attach switch bracket to front of fireplace Figure 19 ...

Page 7: ...Control Module Power cord to the PPO box See Figure 3 3 Turn the fireplace ON using the remote control and confirm operation with main power ON Note You may re install the backup batteries to the battery holder at this point to ensure that fireplace is operational during power outage It is recommended to check and replace the backup batteries at least once a year More frequent battery replacement ...

Page 8: ...XT0016 092214 Proflame 2 Upgrade Kit RX 200 NG LP ...