The Warranty

The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo fireplace, 

there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control 

valve, fibre logs and Power Vent Module. The Glass, plated / painted finishes, and refractory lining are exempt from the warranty.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies.
This Warranty only covers Montigo Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation 

outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, 

and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies 

will, at its option, refund the purchase price of the Montigo Gas Appliance. 
This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which 

are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All 

replacement or repair components will be shipped F.O.B. the nearest The Companies factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo 

Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas 

Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of 

local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies

(2)  The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such 

as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, 

expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs 

or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty 

with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Companies Are Not Responsible For Work Done Without Written Consent

The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent.

Dealers Have No Authority To Alter This Warranty

The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably 

possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The.Companies

 as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp.

Canadian.Heating.Products.Inc..and/or.Montigo.DelRay.Corp..reserves.the.right.to.make.changes.at.any.time,.without.notice,.in.design,.materials,.

specifications,.prices.and.also.to.discontinue.colors,.styles.and.products.

Appendix

Page 8

XG0517 - 031114

Summary of Contents for PVHEX58-300

Page 1: ...er of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cut...

Page 2: ...PVHEX58 300 Vertical Power Vent System Safety Alert Key 3 Introduction 3 Product Dimensions 4 Installation 5 Wiring Diagram 6 7 Appendix 8 9 Appendix A Warranty 8 Appendix B State of Massachusetts 9 Page 2 XG0517 031114 ...

Page 3: ... 20 foot power cord and harness EPVH30 30 foot power cord and harness EPVH40 40 foot power cord and harness EPVH50 50 foot power cord and harness EPVH60 60 foot power cord and harness EPVH70 70 foot power cord and harness EPVH80 80 foot power cord and harness EPVH90 90 foot power cord and harness EPVH100 100 foot power cord and harness Specifications Before Your Begin Voltage 115 Volts Frequency 6...

Page 4: ... 8 203 18 1 4 465 22 1 4 566 17 1 4 439 21 1 4 541 2 51 13 330 4 1 2 114 19 7 8 505 9 1 2 241 6 1 8 156 15 7 8 403 13 330 5 127 8 203 Top View 22 1 4 566 2 51 13 330 4 1 2 114 19 7 8 505 9 1 2 241 6 1 8 156 5 127 8 203 PVHEX58 300 External Horizontal Power Vent Rear View 18 1 4 465 22 1 4 566 17 1 4 439 21 1 4 541 19 7 8 505 9 1 2 241 6 1 8 156 15 7 8 403 13 330 13 330 Power Head Framing Kit Vent ...

Page 5: ...e through the Rough in kit as shown using the strain relief where the wire enters the Rough in kit Figure 2b Securing the Power Vent Rough in Kit Step 3 1 Attach the power cord comming from the Power Head to the receptical in the Rough in box 2 Place the Power Head into the Rough in kit and attach with 4 screws provided 3 Finishing material can be applied to the exterior wall Step 3 Attach the pow...

Page 6: ...earances are maintained for the wiring and conduit When installing the wiring it must never run above the vent run and it must be at least 1 clear of all venting 1 Clearance Wire Figure 3 Conduit and Wiring Wiring Installation 2 Place the Power Head into the Rough in kit and attach with 4 screws provided 3 Finishing material can be applied to the exterior wall Figure 2d Securing the Power Vent Rou...

Page 7: ...White Black Blk Wht Wht Blk Blue Red Brown NC Heat Sensor NO Flue Gas Switch ELECTRICAL CONTROL BOX R3 Gas Valve Wall Switch Fuse 115 Volts 60Hz 5A Post Purge Timer Pre Purge Timer Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Green Black White Switch or Dimmer Not Supplied Power for Lights 115VAC 700W FIREPLACE CONTROLS Red T...

Page 8: ... Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusi...

Page 9: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upo...

Page 10: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0517 031114 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 PVHEX58 300 Power Vent Termination ...

Reviews: