background image

16

Appendix

XG0521 - 180904

Appendix B: Warranty Continued

EXCLUSIONS TO WARRANTY

Corrosion or rust of any kind due to a lack of maintenance, 

inadequate combustion air or improper venting and corrosive 

chemicals/environments, expansion and contraction of metals or 

minor movements of components causing noise are not covered 

by this warranty.
Willful misconduct (i.e. use of the appliance with problems 

known to the purchaser and causing further damages), including 

unauthorized or self-performed 'fixing' or exploration of the 

appliance's internal workings will void the warranty.
Appliances on which the serial number has been altered, defaced, 

removed or made illegible will void the warranty.
Costs incurred for diagnosis, service work, shipping and handling 

of defective or replacement parts are not covered under this 

warranty.

The published warranties are not applicable for any equipment 

manufactured by The Companies that has been sold direct to 

the consumer via internet or auction websites. The Companies 

do not endorse, approve or certify any online sale of its products 

through auction websites, online retailers or any other method 

of online sales direct to consumers.

INVESTIGATION OF CLAIMS AGAINST 

WARRANTY

The Companies reserve the right to investigate any and all claims 

against this warranty and decide upon method of settlement.

The Companies are not responsible for work done without 

written consent of The Companies.

The Companies shall in no event be responsible for any warranty 

work done without first obtaining the Companies written 

consent.

The Companies employees and dealers have no authority to 

make any warranties to neither alter this warranty nor authorize 

any remedies in addition to or inconsistent with those stated 

within this warranty.

IF WARRANTY SERVICE IS NEEDED

To make a claim under this warranty, contact your installing 

dealer or contractor. The installing dealer is responsible for 

providing service and will contact the companies to initiate 

warranted parts replacements. In the event the installing 

dealer is unavailable, contact your nearest authorized Montigo 

dealer (www.Montigo.com) or contact Montigo direct at 

techsupport@ montigo.com. Ensure you have your sales receipt 

and the model and serial number of your appliance.

DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF

If you cannot locate the installing dealer, or nearest dealer/

distributor, you must notify The Companies in writing.

USA Offices

6955 Salashan Parkway
Ferndale WA, 98248

techsupport@montigo.com

Canadian Offices

27342 Gloucester Way

Langley, BC V4W 4A1
techsupport@montigo.com

The terms and conditions of this warranty may be altered or 

amended from time to time without prior notice.
WARRANTY PERIOD: Warranty coverage begins on the date of 

original purchase. In the case of new construction, warranty 

coverage begins on the date of first occupancy of the dwelling 

or six months after the sale of the product by an independent, 

authorized Company dealer/ distributor, whichever occurs 

earlier.

Summary of Contents for PVHIN47-200

Page 1: ...re department Installation and service must be performed by a qualified installer service agency or the gas fitter PVHIN47 200 4 7 INLINE POWER VENT MUST USE IN CONJUNCTION WITH APPLICABLE TERMINATION TMVIN47 12 TMHIN47 24 MTO4 PV MTO4F PV MVTK1SS Read and understand this manual Improper installation adjustment alteration service or maintenance can cause serious injury property damage or even deat...

Page 2: ...X 300 CFM 2700 RPM Introduction Safety Alert Key Indicates a hazardous situation which if not avoided WILL result in death or serious injury or property damage Indicates a hazardous situation which if not avoided WILL result in minor or moderate injury Indicates a hazardous situation which if not avoided COULD result in death or serious injury or property damage Indicates practices that are import...

Page 3: ...ppliance should be inspected before use and at least annually by a professional service person More frequent cleaning might be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean NOTICE NOTICE NOTICE NOTICE NOTICE Contents Safety Alert Key 2 Introduction 2 Section A Befo...

Page 4: ...L DIMENSIONS ARE IN INCHES TOLERANCES 1 8 UNLESS OTHERWISE NOTED CHECKED BY DRAWN BY TC DATE NAME A 6 9 2021 200 SERIES 4 7 INLINE POWER VENT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED Y Products Residential Products Ventilation Systems F...

Page 5: ...lue Gas Box This flue gas box is only to be used with Montigo fireplace systems specifically approved by Montigo 1 6 SIZE DWG NO A REV SHEET 1 OF 3 WEIGHT TMHIN47 24 FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 8 CHECKED BY DRAWN BY TC DATE NAME A 6 28 2021 HORIZONTAL LOUVER BOX TMHIN47 24 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUC...

Page 6: ... 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE CHECKED BY DRAWN BY DATE NAME A 7 11 2016 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED PROPRIETARY AND CONFIDENTIAL G DRAWINGS Terminati...

Page 7: ... clearances 20 min 7 min Allow space for access panel opening min 2 clearance min 2 clearance Maintain standard vent clearances Mounting on a combustible is permitted provided the clearances are adhered to Mounting on a combustible is permitted provided the clearances are adhered to Grey Non Combustible Zone Direction of flow Direction of flow Direction of flow ...

Page 8: ...e four feet 4 0 Maximum allowable vent run must be reduced by ten feet 10 0 for every 90 elbow added Multi elbow installations are possible up to a maximum one hundred feet with three 3 90 elbows Minimum vent run from Fireplace to Power Vent must be two feet 4 0 Maximum allowable vent run must be reduced by ten feet 10 0 for every 90 elbow added Minimum distance from unit collar to PV 4 MVTK1SS TM...

Page 9: ...tic showin in Figure 14 Section 3 Ensure that the proper clearances are maintained for the wiring and conduit When installing the wiring it must never run above the vent pipe and it must be at lest 1 clear of all venting and other hot surfaces 1 Clearance Wire Power Vent Wiring C BLUE BROWN BLACK WHITE BLACK GREEN 6 PIN MOLEX CONNECTOR KEY WAY BLUE AIR SWITCH RED ...

Page 10: ... Wht GREEN BLACK POWER VENT AIR SWITCH YELLOW YELLOW YELLOW YELLOW BLACK GREEN RED BROWN WHITE CPI IPI SWITCH WHITE SW1 BLACK WHITE BLACK WHITE GREEN VARIABLE SPEED COMFORT FANS OPTIONAL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR MAIN ON OFF WIRED TO WALL SWITCH OPTIONAL OR SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANG OPTIONAL STEPPER MOTOR E 6 10 6 Wht Wht GREEN BLACK POWER ...

Page 11: ...ft until it clicks off then right click ON this is maximum speed If the fireplace cycles on off due to windy conditions increase the speed of the venter to overcome this situation After 20 minutes of running turn speed control to the right the motor speed will slow keep turning the control knob to the right until the burner turns off This point is the slowest speed the venter may run in this insta...

Page 12: ...4 FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 8 CHECKED BY DRAWN BY TC DATE NAME A 7 16 2021 HORIZONTAL LOUVER BOX TMHIN47 24 INED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED C VAULT _CUSTOM VENTILATION SYSTEMS BOXES VB Vent WIP TMHIN47 24 Frid...

Page 13: ...e installation of the frame prior to installation of the termination 1 Frame the termination opening to 12 x 12 2 Secure the MSR Frame to the exterior sheathing of the structure 3 FastentheterminationtotheMSRFrameusingaminimumof4screws Installation of termination frame at time of framing in masonry Terminations with a BSR frame allow the installation of the frame in masonry prior to the installati...

Page 14: ...mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30 cm minimum K clearance to a mechanical air supply inlet 6 feet 1 8 m minimum L clearance above paved side walk or a paved driveway located on public property 7 feet 2 1 m minimum M clearance under veranda porch deck or balcony 0 inches 0 cm minimum N 18 minimum chase height O 4 feet clearance fr...

Page 15: ... gas NG or liquefied petroleum LP only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the appliance produce excessive temperatures will result in a fire hazard and void all warranties This warranty is transferable The appliance must remain in its original place of installation to be valid If the components of the appliance covered by this warran...

Page 16: ...ritten consent of The Companies The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent The Companies employees and dealers have no authority to make any warranties to neither alter this warranty nor authorize any remedies in addition to or inconsistent with those stated within this warranty IF WARRANTY SERVICE IS NEEDED To ma...

Page 17: ...The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Appendix C Amendment Gas Fireplace Equipment sold in the State of Massachusetts 5 08 Modifications to NFPA 54 Chapter 10 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Page 18: ...XG0521 180904 Installation Maintenance Manual PVHIN47 200 PVHIN47 200 Inline Power Vent Inline Power Vent ...