PVVEX58-300 & PVVEX510-300 Horizontal Power Vent
Page 11
XG0518 - 070714
Top Cover
Top Cover
Screws x 4 plcs
Screw Locations
x 4 plcs
Wind Baffle
Rain Skirt
Screw Locations
x 5 plcs
Top Separator
Step 1:
a) Remove the 4 outer screws
that fasten the Top Cover to
the termination
b) Remove the Cover.
PVVEX58-300
Motor Removal / Servicing
Step 2:
a) Remove the 4 outer screws
that fasten the Wind Baffle to
the termination.
b) Lower the Wind Baffle to
rest on the Rain Skirt.
Step 3:
a) Remove the 5 outer screws
that fasten the Top Separator
to the termination.
b) Remove the Top Separator.
Capacitor Removal and Servicing
Step 1:
Remove the 4 outer screws that fasten the top cover to the
termination. Remove the cover.
Figure 5.
Capacitor Replacement [REC1252]
Turn off power and gas before servicing.
Figure 5a.
Step 2:
Cut zap straps.
Step 3:
Unscrew ground wire/capacitor bracket from motor.
WARNING: Save this screw.
Figure 5b.
Step 4:
Cut brown wire from motor and black wire from capacitor.
Figure 5c.
Step 5:
Cut black fibre wire from power cable and blue wire from
motor.
Figure 5d.
Service