Step 7:
Cut the white fibre wire from the power cable.
Figure 6f.
Step 8:
Remove 4 screws securing the motor mounting plate.
Figure 6g.
Figure 6h.
Step 9:
Lift out motor and capacitor.
REC1253
Figure 6i.
Step 10:
Drop new motor assembly into the power vent and screw
with supplied 4 screws and star washers. Line up cut out in motor
mounting plate with electrical conduit.
Figure 6j.
Step 11:
Remove the ground wire screw from the motor.
NOTE
:
Save this screw for later.
Figure 6k.