Step 1:
Construct a chase box around the vent penetration with
Figure 2a.
Chase box dimensions
Installing the power vent
Figure 2.
Power vent components Exploded View
Step 2:
Install the electrical harness (EPVH-10-100) that will com-
municate with the Power Vent. Run vent pipe from the fireplace to the
chase. Make sure the last section is female end up and is flush with
the top of the chase without going above it. See figure 2b.
Figure 2b.
Installing the Rough-in Kit.
Figure 2c.
Installing the Rough-in Kit.
20"
Max
20"
Max
PVVEX58-300
10 58 "
270
Min
10 58 "
270
Min
24
Min
PVVEX510-300
13"
[330]
Note:
Follow local and/or national code requirements for roof
clearances.
Step 3:
Remove the last section of vent pipe and put off to the side
to be used later. Take the rough in box from the power
Installation