Maintenance
Servicing the Burner
Follow the steps below to remove the burner to service the unit.
Remove the safety screen and outer and inner glass.
Figure 29.
.Remove.4.rail.screws.found.at.the.end.of.the.rails..
Figure 29c.
.
.
.Remove.4.screws.and.then.remove.gas.connection.cover.
Figure 29e.
.After.removing.the.appropriate.fasteners,.remove.the.burner.
assembly.
Figure 29d.
.Disconnect.the.flexible.gas.connection.line..
Figure 29f.
.Remove.the.valve.cover.to.gain.access.to.the.valves..
Step 1:
Step 2:
Remove firestones
Step 3:
Step 4:
Lift one end of the rail up above the firebox ceiling baffle.
Pull the other end out the front of the fireplace.
Step 5:
Step 6:
Step 7:
Figure 29g.
.Gas.Valve.and.Pressure.Sensor
Figure 29a.
.
Figure 29b.
.