XG0680 - 080321
3
General
6 37
64 "
4 15
16 "
3 15
64 "
USE #8
SCREWS FOR
MOUNTING
2 19
32 "
4 14 "
OVERALL
DIMENSIONS
MOUNTING
DIMENSIONS
(SHOWN w/o RECEIVER)
Use #8 screws
for mounting
MOUNTING
DIMENSIONS
(Shown w/o receiver)
1. Attach the remote control box within 3 feet of main control box. (the
remote receiver is attached with velcro and may have to be removed
to access mounting screw slots.
Wiring Instructions
(remote box to main control box)
A qualified electrician must install the remote control system.
Turn off all power and gas to fireplace.
This remote control system must be installed exactly as outlined in
these instructions. Read all instructions completely before attempting
installation. Follow instructions carefully during installation. Any
modifications of this remote control or any of its components will void
the warranty and may pose a fire hazard.
WARNING
ITEM No.
PART No.
DESCRIPTION
QTY. REV.
1 EC1458 JUNCTION BOX 9100 NO TERM 125x167x82mm
1
2 HW2212 VELCRO, 1"x2.75" MATED HOOK/LOOP
1
3 RX5010-
RECEIVER ON/OFF 110V RECEIVER FOR TOUCHSCREEN REMOTE
1
4 EC1462 NYLON STRAIN RELIEF CONNECTOR, 1/2"
1
1:2
SIZE DWG. NO.
A
REV.
SHEET 1 OF 3
WEIGHT:
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CHECKED BY
DRAWN BY
DATE
NAME
18/08/2016
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
August-18-16 11:16:59 AM
SCALE
P42 REMOTE CONTROL
ELECTRICAL BOX
ECA102
2. Locate the wire running from the remote receiver and remove the
wire nuts at the ends of the wires.
3. Feed the wire into the control box side.
4. Connect the wires shown above from the remote receiver to the wires
from the control box. Black to black, red to red, and white to white.
Loosen relief connector nuts before
feeding wire through
5. After the wires are connected, tighten the strain relief connector nuts.
Summary of Contents for RXM40VACVO
Page 5: ...5 Notes XG0680 021121 ...