12
4.3. What to do if something goes wrong
The spark ignition will not operate:
-
Check there is not a power cut
-
Check there is power to the electric socket/
appliance
The gas burners will not operate:
- Have you pushed in the control knob and maintained pressure
for at least 10 seconds after the burner has lit?
4.3. Specifications
Please refer to the Rating Label on the appliance –
example shown below (MON-GH60BG).
Product Name
Gas hob
Model Number
MON-GH60BG
Cat
I3B/P(50)
I3+(28-30/37)
I3B/P(30)
I2L
I2H/I2E/I2E+ II2H3+
II2H3B/P(30) II2E+3+
Country code
DE,AT,CH,LU,S
K
BE, CH, CY, CZ,
ES, FR, GB, GR,
IE, IT, LT, LU, LV,
PT, SK, SI.
BE, CY, DK, EE,
FR, GB, HU, IT,
LT, NL, NO, SE,
SI, SK, RO, HR,
TR, BG, IS, LU,
MT, FI
NL
AT,CH,CZ,DK,E
S,FI,GB,GR,IE,
IS,IT,PT,SE,SI,S
K,DE,LU,GE,
FR
CH,
CZ,ES,GB,GR
,IE, IT,PT,SI
CH,CZ,DK,FI,G
R,SE,SI,SK
BE, FR
Categories
G30 Butane and
G31 Propane at
50mbar
G30
Butane
at 28-30mbar and
G31 Propane at
37mbar
G30 Butane and
G31 Propane at
30mbar
G25
Methane
25mbar
G20 Methane
20mbar
G20
at
20mbar, G30
Butane
at
28-30mbar
and
G31
Propane
at
37mbar
G20 at 20mbar,
G30 Butane and
G31 Propane at
30mbar
G20/G25
at
20/25mbar, G30
Butane
at
28-30mbar and
G31 Propane at
37mbar
Direct Country
of Destination
AT,BE,BG,CH,CY,CZ,DE,DK,EE,ES,FR,FI,GE,GB,GR,HR,HU,IE,IT,IS,LT,LU,LV,MT,NL,NO,
PT,RO,SE,SI,SK,TR,NL
Nominal Heat Input
Qn=Rapid burner: 3.0kW; Semi-rapid burner: 1.75kW; Auxiliary 1.0kW
Total Heat Input
∑
Qn=7.5 kW( 546 g/h)
Electrical Supply
CAUTION:
This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated space. Read the
instructions before installing or using this appliance.
2531-18
Pin 2531CS-0060
20-240 V~, 50Hz-60Hz, 0.6W