20
1
Press
Pull to open
2
the guide rails
“F” nail 18Ga.
Press
against the
front part
3
Staples 18Ga.
WARNING:
Point the device away from yourself
and from others when you are loading. Mistakes
can lead to a risk of injury. Do not load the device
when making contact with the work surface as
this may cause injury.
Removing nails:
1. Disconnect the compressed air supply.
2. Press the magazine cover and remove the
magazine.
3. Grasp the strips of nails from the top and
remove them from the magazine.
Methods for use
The device is equipped with a retainer. It can only
be triggered when the retainer is pushed down.
CAUTION
•
Do not press the device against the wood using
excessive pressure.
•
In the event of rebound, break contact between
the device and the wood.
1. Pull the trigger without the device touching
the work surface.
2. Press the retainer against the work surface to
3. Moving the device along the work surface
with wave-like movements against the work
the trigger.
NOTE:
Handle nails and packaging carefully! The
nail binding may break if handled improperly,
1.
2. Remove all nails.
3.
device.
4.
Use in cold weather
CAUTION:
Do not use the device in freezing
thawed before use. Frozen moisture can impair
increased risk of injury or damage to the device.