Replacement Parts List

PFH10

DESCRIPTION

 

PART #

1 RPVL3857

BACK COVER

2 RPVL3863

BACK COVER GASKET

3 RPVALV12

TANK VALVE

4 RPCA3682

CONNECTION BOARD

5 RPPFHPCK     HARDWARE PACKET

6 RPVALV08

PRESSURE RELIEF VALVE

7 RPVL2968

HOUSING BODY

8 RPGK3880

WALL MOUNT GASKET

9 RPVL3858

HOUSING BRACKET

10 RPFTM2425G   WALL MOUNT BRACKET

11 RPRSORG24    HOUSING ORING

12 RPVL3860

HOUSING NUT

13 RP76VL2015     PC BOARD

14 RPVL2969

CAMERA SLED ASSEMBLY

15 RPVL2965

HOUSING ASSEMBLY

16 RPVL3888

LANYARD SLED

17 RPVL2972

FRONT WINDOW ASSEMBLY

9

PSI

0

5

10

15

20

25

30

Fill Valve

Over - Pressure Relief Valve

Connectors

Pressure Gauge

NOT INCLUDED

Air Chuck

 

After purging and refilling, check 
the housings pressure.  It should be 
around 5-7psi (0.35-0.5bar).

•  Después de purgar y de rellenar, compruebe la 

presión de las cubiertas. Debe estar alrededor de 
5-7psi (0.35-0.5bar). 

•  Après la purge et le remplissage, vérifiez la pression 

de logements. Elle devrait être autour de 5-7psi 
(0.35-0.5bar). 

•  Nachdem Sie bereinigt haben und wieder gefüllt 

haben überprüfen Sie den Gehäusedruck. Er sollte 
um 5-7psi (0.35-0.5bar) sein.

•  Após a remoção e o reenchimento, verific a pressão 

das carcaças. Deve ser em torno de 5-7psi 
(0.35-0.5bar). 

•  Dopo l'eliminazione dell'inceppo ed il riempimento, 

controlli la pressione degli alloggiamenti. Dovrebbe 
essere intorno a 5-7psi (0.35-0.5bar).

22

Summary of Contents for DFH10C2W

Page 1: ...span included heater blower with feed thru wall pole mount supports af PoE cameras adjustable sunshield DFH10C2W Dust Proof tubular housing 24Vac or 12Vdc input heater blower with feed thru wall pole mount DFH10C2WY Dust Proof tubular housing 24Vac or 12Vdc input heater blower with feed thru wall pole mount adjustable sunshield DFH10C8WY Dust Proof tubular housing PoE input with Dynamic Power Allo...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ...spect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the Internat...

Page 4: ...ough hides and protects cables Pop Out Tabs allows for pole mounting Rear Access Panel acts as internal J Box Installers Connection Board allows for easy hook ups Lanyard Cable safely retains housing during installation Durable and Attractive grite color powder coated finish increased corrosion protection finish available Optional Accessory ...

Page 5: ...oto 12Vdc 11W Aucun appareil photo 24Vac 29W Keine Kamera 12Vdc 11W Keine Kamera 24Vac 29W Nenhuma câmera 12Vdc 11W Nenhuma câmera 24Vac 29W Nessuna macchina fotografica 12Vdc 11W Nessuna macchina fotografica Electrical Specifications Power 12VDC Class 2 Only Français Deutsch Italiano Portuguese Español English ADDITIONAL DETAIL TO BE UPDATED IN FUTURE REVISIONS ...

Page 6: ...enenplatte zusammenbauen stellen Sie sicher dass alle VerdrahtungsZugangslöcher Einfassung in Richtung zur Rückseite des niedrigen Einfassungszugangsportals sind CUIDADO Ao montar o suporte certifique se que todos os furos de acesso da fiação são revestimento para a parte traseira do portal baixo do acesso das montagens ATTENZIONE Nel montare il montaggio la staffa si assicura che tutti i fori di ...

Page 7: ...estellt Una a montagem à parede com a ferragem apropriada não fornecida Attacchi il supporto alla parete con fissaggi adatti non forniti WALL MOUNTING If attaching to pole first break away tabs with pliers and remove 4 strap plugs Si atan al poste el primeros rompen lejos lengüetas con los alicates y quitan 4 los enchufes de la correa Si attachant au poteau les premiers cassent loin des étiquettes...

Page 8: ...Alimenti il cavo tramite la staffa perfori gli ugelli della guarnizione come stato necessario Disponga la guarnizione come indicata Cable Gasket Nipples 5 6 Feed cable through back of bracket or bottom access point Then follow instructions from previous block Alimente el cable a través detrás del soporte o del punto de acceso inferior Entonces siga las instrucciones del bloque anterior Alimentez l...

Page 9: ... tutti collegamenti nessecary dei collegamenti A Slightly loosen B Completely loosen RJ45 568B Power BNC Communication 9 Use provided Key to remove the front part of the housing El uso proporcionó llave para quitar la parte delantera de la cubierta L utilisation a fourni la clef pour enlever la partie avant du logement Gebrauch lieferte Schlüssel um das Vorderteil des Gehäuses zu entfernen O uso f...

Page 10: ...a alimentación se suministra No hacer esto puede resultar en daños a la vivienda y anulará todas las garantías Assurez vous que le sélecteur de tension est réglé pour l entrée et la tension d alimentation appareil photo avant de l alimentation est fournie Le défaut de ce faire peut entraîner des dommages au logement et annulera toutes les garanties Stellen Sie sicher dass der Spannungswahlschalter...

Page 11: ...ektiv an wenn erforderlich Instale a câmera usando os parafusos fornecidos e o espaçador de borracha à lente center se necessário Stalli la macchina fotografica usando le viti fornite ed il distanziatore di gomma all obiettivo concentrare se necessario Loosen the screws shown on the picture and turn the camera sled ring to the desired angle and re tighten Afloje los tornillos demostrados en el cua...

Page 12: ...3 volte rimuovere tutta l umidità Depress to Purge Pressure Fill Schraeder Valve Pressure Fill Schraeder Valve Air Chuck Place the air chuck on the fill valve and begin filling until pressure relief valve opens Coloque la tirada del aire en la válvula del tanque y comience a llenar hasta que la válvula de descarga de presión se abra Placez le mandrin d air sur la valve de réservoir et commencez à ...

Page 13: ...5 30 Fill Valve Over Pressure Relief Valve Connectors Pressure Gauge NOT INCLUDED Air Chuck After purging and refilling check the housings pressure It should be around 5 7psi 0 35 0 5bar Después de purgar y de rellenar compruebe la presión de las cubiertas Debe estar alrededor de 5 7psi 0 35 0 5bar Après la purge et le remplissage vérifiez la pression de logements Elle devrait être autour de 5 7ps...

Page 14: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via the Online Product Registration Form at www videolarm com productregistration jsp Register your recent Moog Videolarm purchases and benefit from the following Simple and Trouble Free RMA process Adde...

Reviews: