background image

IMPORTANT SAFEGUARDS

SAFETY PRECAUTIONS

UNPACKING

SERVICE

1     Read these instructions.
2    Keep these instructions. 
3    Heed all warnings 
4    Follow all instructions.
5    Do not use this apparatus near water.
6    Clean only with damp cloth.
7    Do not block any of the ventilation openings.  Install in accordance with the  

  manufacturers instructions.

8    Cable Runs- All cable runs must be within permissible distance.
9    Mounting - This unit must be properly and securely mounted to a supporting  

  structure capable of sustaining the weight of the unit.

Accordingly:

a.  The installation should be made by a qualified installer.
b.  The installation should be in compliance with local codes.
c.  Care should be exercised to select suitable hardware to install the unit, taking into 

account both the composition of the mounting surface and the weight of the 
unit. 

10   Do not install near any heat sources such as radiators, heat registers, stoves, or other  

  apparatus ( including amplifiers) that produce heat.

11   Do not defeat the safety purpose of the polarized or grounding-type plug.  A  

  polarized plug has two blades with one wider than the other.  A grounding type  
  plug has two blades and a third grounding prong.  The wide blade or the third  
  prong are provided for your safety.  When the provided plug does not fit into your  
  outlet, consult an electrician for replacement of the obsolete outlet.

12   Protect the power cord from being walked on or pinched particularly  at plugs,  

  convenience receptacles, and the point where they exit from the apparatus.

13   Only use attachment/ accessories specified by the manufacturer.
14   Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer,  

  or sold with the apparatus.  When a cart is used, use caution when moving the cart/           
  apparatus combination to avoid injury from tip-over.

15   Unplug this apparatus during lighting storms or when unused for long periods of time.
16   Refer all servicing to qualified service personnel.  Servicing is required when the  

  apparatus has been damaged in any way, such as power-supply cord or plug is  
  damaged, liquid has been spilled of objects have fallen into the apparatus, the  
  apparatus has been exposed to rain or moisture, does not operate normally, or  
  has been dropped.

Be sure to periodically examine the unit and the supporting structure to make sure that the 
integrity of the installation is intact. Failure to comply with the foregoing could result in the 
unit separating from the support structure and falling, with resultant damages or injury to 
anyone or anything struck by the falling unit.

Unpack carefully. Electronic components can be 

damaged if improperly handled or dropped. If an item 

appears to have been damaged in shipment, replace

it properly in its carton and notify the shipper.

Be sure to save:
1  The shipping carton and packaging material.

They are the safest material in which to make 

future shipments of the equipment.

2  These Installation and Operating Instructions.

If technical support or service is needed, contact us 

at the following number:

The lightning flash with an arrowhead 

symbol, within an equilateral triangle, is 

intended to alert the user to the presence 

of non-insulated “dangerous voltage” 

within the product’s enclosure that may be 

of sufficient magnitude to constitute a risk 

to persons.

Este símbolo se piensa para alertar al usuario a la 

presencia del “voltaje peligroso no-aisIado” dentro del 

recinto de los productos que puede ser un riesgo de 

choque eléctrico.

Ce symbole est prévu pour alerter I’utilisateur à la 

presence “de la tension dangereuse” non-isolée dans la 

clôture de produits qui peut être un risque de choc 

électrique.

Dieses Symbol soll den Benutzer zum Vorhandensein der 

nicht-lsolier “Gefährdungsspannung” innerhalb der 

Produkteinschließung alarmieren die eine Gefahr des 

elektrischen Schlages sein kann.

Este símbolo é pretendido alertar o usuário à presença 

“di tensão perigosa non-isolada” dentro do cerco dos 

produtos que pode ser um risco de choque elétrico.

Questo simbolo è inteso per avvertire I’utente alla 

presenza “di tensione pericolosa” non-isolata all’interno 

della recinzione dei prodotti che può essere un rischio di 

scossa elettrica.

The exclamation point within an equilateral 

triangle is intended to alert the user to 

presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

Este símbolo del punto del exclamation se piensa para 

alertar al usuario a la presencia de instrucciones 

importantes en la literatura que acompaña la 

aplicación.

Ce symbole de point d’exclamation est prévu pour 

alerter l’utilisateur à la presence des instructions 

importantes dans la littérature accompagnant 

l’appareil.

Dieses Ausruf Punktsymbol soll den Benutzer zum 

Vorhandensein de wichtigen Anweisungen in der 

Literatur alarmieren, die das Gerät begleitet.

Este símbolo do ponto do exclamation é pretendido 

alertar o usuário à presença de instruções importantes 

na literatura que acompanha o dispositivo.

Questo simbolo del punto del exclamaton è inteso per 

avvertire l’utente alla presenza delle istruzioni importanti 

nella letteratura che accompagna l'apparecchio.

TECHNICAL SUPPORT

AVAILABLE 24 HOURS

1800 554 -1124

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER ( OR BACK).  NO USER- SERVICE-

ABLE PARTS INSIDE.  REFER SEVICING TO 

QUALIFIED SERVICE PERSONNEL.

Summary of Contents for Freedom Dome LDW75C2N

Page 1: ...l Rights Reserved Installation and Operation Instructions for the following model LDW75C2N Ruggedized dome enclosure with space for peripheral equipment 110 220VAC input Designed to work with Moog Videolarm IP Ready camera housings Freedom Dome Modular All Weather Dome Enclosure W81 IN5477 07 25 2012 www moogvideolarm com ...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ...spect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the Internat...

Page 4: ... poteau sera incorporé dans l installation électrique du bâtiment Zugeführte Energie 110Vac 220Vac 1A 0 5A Leistungsaufnahme 1Amp 120 Watt an 120Vac Abgabeleistung 96Va an 24Vac 52 Watt Heizung Gebläse Kamera Energie 32 Watt Ein aller Pfostenhauptschalter mit einem Kontakt von 3mm mindestens in jedem Pfosten wird in der elektrischen Installation des Gebäudes enthalten Poder de entrada 110Vac 220Va...

Page 5: ...IGHT PLUG FOR 3G ANTENNA BULKHEAD CONNECTOR HOLE LIQUID TIGHT PLUG FOR OPTIONAL MAIN POWER HOLE LIQUID TIGHT PLUG FOR OPTIONAL MAIN POWER HOLE LIQUID TIGHT STRAIN RELIEF FOR MAIN POWER HOLE Power Feed Locations ...

Page 6: ...ked holes to attach steel straps La unidad de LDW75C2N está lista para montar Utilice los agujeros marcados para atar las correas de acero L unité de LDW75C2N est prête à monter Employez les trous marqués pour attacher les courroies en acier LDW75C2N Maßeinheit ist bereit anzubringen Benutzen Sie markierte Löcher um Stahlbügel anzubringen A unidade de LDW75C2N está pronta para montar Use furos mar...

Page 7: ...le scanalature fori alle labbra sulla staffa Shows the wall mount option of hanging unit and where to secure the bolt Demuestra la opción del montaje de la pared de la unidad colgante y donde asegurar el perno Montre l option de bâti de mur de l unité accrochante et où fixer le boulon Zeigt die Wandeinfassungswahl der hängenden Maßeinheit und wo man den Schraubbolzen sichert Mostra a opção da mont...

Page 8: ... and washers to secure the housing in place Termine el cableado eléctrico necesario Utilice los pernos y las arandelas proporcionados para asegurar la cubierta en el lugar Accomplissez le câblage électrique nécessaire Employez les boulons et les rondelles fournis pour fixer le logement en place Schließen Sie die notwendige elektrische Verdrahtung ab Benutzen Sie die zur Verfügung gestellten Schrau...

Page 9: ...ES LEFT RIGHT 3 RP30VL3708 HINGE PLATE 4 RP96GK3710 TOP COVER GASKET 5 RP70TRANS12 REPLACEMENT TRANSFORMER 96 VA 6 RP954GLTCH LATCHE SIERRA 210 120SS 7 RP30VL3701 WALL MOUNT BRACKET 8 RP71VLBL03 Fusion Dome BLOWER 40x40x10mm 1 0 watt RoHS 9 RP40BR3510 FD7 MAIN CAMERA BRACKET ASSEMBLY 10 RP25DCR73000 Clear Dome WHITE Trimring R7 style ...

Page 10: ...HP RHW LDW et IGDW ajouter un supplémentaires 13mm d écartement à des hauteurs indiquées ci dessous Für alle RHP RHW LDW und IGDW Modelle fügen Sie einen zusätzlichen 13mm Abstandhalter zu Höhen unten gezeigt Para todos os modelos RHP RHW LDW e IGDW adicionar um adicional de 13mm espaçador para alturas abaixo Per tutti i modelli RHP RHW LDW e IGDW aggiungere un ulteriore 13mm spacer ad altezze ind...

Page 11: ... Mounting holes AVIGILON HD Dome Series 3 8 3 100mm 3 1 2 1 Mounting holes ARECONT AV8185 AV8365 AV20185 AV20365 4 8 x 75mm 1 2 4 4 ...

Page 12: ... Mounting holes AXIS 215 4 8 4 100mm 4 1 2 1 Mounting holes BASLER BIP2 1000C DN BIP2 1300C DN BIP D1000C DN BIP D1300C DN 3 8 3 100mm 3 1 2 1 Mounting holes AXIS 233D 4 8 4 25mm 4 1 ...

Page 13: ... Mounting holes CANON VB M40 64mm 2 1 1 1 Mounting holes CANON VB C60 64mm 2 1 1 1 Mounting holes CANON VB C300 88mm 1 1 1 1 2 ...

Page 14: ... Mounting holes ELMO PTC 400C 4 8 4 100mm 4 1 2 Mounting holes JVC VN V686BU VN V685U 3 8 3 38mm 1 Mounting holes PANASONIC BB HCM580 581 1 1 88mm 1 1 2 x ...

Page 15: ... Mounting holes PANASONIC SC386 4 8 4 25mm 4 1 Mounting holes PANASONIC WV CS580 Series 38mm 4 8 1 Mounting holes PANASONIC WV CS574 4 8 4 50mm 4 2 ...

Page 16: ... Mounting holes 4 PANASONIC WV CS954 WV NS954 13mm 4 8 Mounting holes PANASONIC WV NS202 WV SC385 WV SC384 4 8 4 75mm 4 1 2 Mounting holes PIXORD P 463 3 8 3 25mm 3 1 ...

Page 17: ... Mounting holes SONY RX Series RX530 RX550 RX570 4 M3 4 Mounting holes SANYO VCC HD 5400 2 8 2 64mm 2 Mounting holes SONY EP ER Series 520 550 580 4 8 4 4 38mm 1 ...

Page 18: ... Mounting holes 13mm SONY SNC RZ25 2 M3 1 1 1 2 Mounting holes 4 SONY SNC RH RS Series RH124 RS44 RS46 25mm 4 8 1 Mounting holes 50mm 2 SONY SNC RZ50 2 M3 1 1 1 2 ...

Page 19: ... Mounting holes TOSHIBA IK WB16A 1 1 88mm 1 1 2 Mounting holes TOSHIBA IK WB21A 4 8 4 75mm 4 1 2 Mounting holes VIDEO IQ VIQ CT CID CRD HD CRD 4 M4x10 4 75mm 1 2 ...

Page 20: ...pending on the product purchased See full warranty details at www moogvideolarm com technical support warranty plan Register Your ProductsOnline Please take a few moments to register your purchase via the Online Product Registration Form at www moogvideolarm com technical support product registration Register your recent Moog Videolarm purchase and benefit from the following Simple and Trouble Fre...

Reviews: