background image

IMPORTANT SAFEGUARDS

SAFETY PRECAUTIONS

UNPACKING

SERVICE

1     Read these instructions.
2    Keep these instructions. 
3    Heed all warnings 
4    Follow all instructions.
5    Do not use this apparatus near water.
6    Clean only with damp cloth.
7    Do not block any of the ventilation openings.  Install in accordance with the  

  manufacturers instructions.

8    Cable Runs- All cable runs must be within permissible distance.
9    Mounting - This unit must be properly and securely mounted to a supporting  

  structure capable of sustaining the weight of the unit.

Accordingly:

a.  The installation should be made by a qualified installer.
b.  The installation should be in compliance with local codes.
c.  Care should be exercised to select suitable hardware to install the unit, taking into 

account both the composition of the mounting surface and the weight of the 
unit. 

10   Do not install near any heat sources such as radiators, heat registers, stoves, or other  

  apparatus ( including amplifiers) that produce heat.

11   Do not defeat the safety purpose of the polarized or grounding-type plug.  A  

  polarized plug has two blades with one wider than the other.  A grounding type  
  plug has two blades and a third grounding prong.  The wide blade or the third  
  prong are provided for your safety.  When the provided plug does not fit into your  
  outlet, consult an electrician for replacement of the obsolete outlet.

12   Protect the power cord from being walked on or pinched particularly  at plugs,  

  convenience receptacles, and the point where they exit from the apparatus.

13   Only use attachment/ accessories specified by the manufacturer.
14   Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer,  

  or sold with the apparatus.  When a cart is used, use caution when moving the cart/           
  apparatus combination to avoid injury from tip-over.

15   Unplug this apparatus during lighting storms or when unused for long periods of time.
16   Refer all servicing to qualified service personnel.  Servicing is required when the  

  apparatus has been damaged in any way, such as power-supply cord or plug is  
  damaged, liquid has been spilled of objects have fallen into the apparatus, the  
  apparatus has been exposed to rain or moisture, does not operate normally, or  
  has been dropped.

Be sure to periodically examine the unit and the supporting structure to make sure that the 
integrity of the installation is intact. Failure to comply with the foregoing could result in the 
unit separating from the support structure and falling, with resultant damages or injury to 
anyone or anything struck by the falling unit.

Unpack carefully. Electronic components can be 

damaged if improperly handled or dropped. If an item 

appears to have been damaged in shipment, replace

it properly in its carton and notify the shipper.

Be sure to save:
1  The shipping carton and packaging material.

They are the safest material in which to make 

future shipments of the equipment.

2  These Installation and Operating Instructions.

If technical support or service is needed, contact us 

at the following number:

The lightning flash with an arrowhead 

symbol, within an equilateral triangle, is 

intended to alert the user to the presence 

of non-insulated “dangerous voltage” 

within the product’s enclosure that may be 

of sufficient magnitude to constitute a risk 

to persons.

Este símbolo se piensa para alertar al usuario a la 

presencia del “voltaje peligroso no-aisIado” dentro del 

recinto de los productos que puede ser un riesgo de 

choque eléctrico.

Ce symbole est prévu pour alerter I’utilisateur à la 

presence “de la tension dangereuse” non-isolée dans la 

clôture de produits qui peut être un risque de choc 

électrique.

Dieses Symbol soll den Benutzer zum Vorhandensein der 

nicht-lsolier “Gefährdungsspannung” innerhalb der 

Produkteinschließung alarmieren die eine Gefahr des 

elektrischen Schlages sein kann.

Este símbolo é pretendido alertar o usuário à presença 

“di tensão perigosa non-isolada” dentro do cerco dos 

produtos que pode ser um risco de choque elétrico.

Questo simbolo è inteso per avvertire I’utente alla 

presenza “di tensione pericolosa” non-isolata all’interno 

della recinzione dei prodotti che può essere un rischio di 

scossa elettrica.

The exclamation point within an equilateral 

triangle is intended to alert the user to 

presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

Este símbolo del punto del exclamation se piensa para 

alertar al usuario a la presencia de instrucciones 

importantes en la literatura que acompaña la 

aplicación.

Ce symbole de point d’exclamation est prévu pour 

alerter l’utilisateur à la presence des instructions 

importantes dans la littérature accompagnant 

l’appareil.

Dieses Ausruf Punktsymbol soll den Benutzer zum 

Vorhandensein de wichtigen Anweisungen in der 

Literatur alarmieren, die das Gerät begleitet.

Este símbolo do ponto do exclamation é pretendido 

alertar o usuário à presença de instruções importantes 

na literatura que acompanha o dispositivo.

Questo simbolo del punto del exclamaton è inteso per 

avvertire l’utente alla presenza delle istruzioni importanti 

nella letteratura che accompagna l'apparecchio.

TECHNICAL SUPPORT

AVAILABLE 24 HOURS

1800 554 -1124

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER ( OR BACK).  NO USER- SERVICE-

ABLE PARTS INSIDE.  REFER SEVICING TO 

QUALIFIED SERVICE PERSONNEL.

Summary of Contents for PDDW10CN2

Page 1: ...iver 120VAC heater Tough enough to stop a 9mm bullet PDDW10CR1 Pressurized Version DeputyDome Series 10 gauge Steel Bullet Resistant Outdoor dome PTZ Camera System with 26x Day Night Camera onboard receiver driver 120VAC heater Tough enough to stop a 9mm bullet Before attempting to connect or operate this product please read these instructions completely CERTIFIED 81 IN5210 10 07 2010 Product Info...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ... other acts of God i e hurricanes earthquakes failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the International Security Industry Organization written in product instructions or recommended in the service manual for the Product Furthermore Videolarm shall have no liability where a sche...

Page 4: ...urateur électronique 22 étapes DDW10CR1 N 115 VAC 90 VA 0 8 Amps DDW10CR2 N 24 VAC Kategorie 2 90 VA 3 75Amps KAMERA SPEZIFIKATIONEN Entschließung 470 TVL NTSC 460TVL PAL Minimale Ablichtung 1 0 1 0 Lux Summen Verhältnis 26x 3 5 91mm optisch 321x digital Format Weiße Balance Automobil Elektronischer Blendenverschluß 22 Schritte DDW10CR1 N 115 VAC 90 vA 0 8 ampères DDW10CR2 N 24 VAC classe 2 90 vA ...

Page 5: ...re a carcaça no sentido horário para remover a carcaça da montagem A montagem da parede pode agora ser unida à parede Allenti tutti i dadi della flangia e giri l alloggiamento in senso orario per rimuovere l alloggiamento dal supporto Il supporto della parete può ora essere fissato alla parete Bolt Housing securely to wall or pole Cubierta de perno con seguridad a la pared o al poste Logement de b...

Page 6: ...Alarm In 1 RXB TXB TXA Heater Blower Heater Blower Camera Power Camera Power Shield Video NC RXA NC Wire Gauge Total vA consumed 5 22 75 20 1 0 18 1 5 16 2 5 14 4 12 6 10 MM 2 AWG 5 5 ft m 400 121 600 182 960 292 10 120 36 5 180 54 9 300 91 4 480 146 800 243 1300 396 20 86 27 1 141 43 0 225 68 6 358 109 571 174 905 275 1440 438 30 65 19 8 90 27 4 130 39 6 225 68 6 350 106 525 160 830 252 40 44 13 ...

Page 7: ...ligns with the tabs Afloje el perno cautivo como shownSlide Pan Inclinación atrás hasta que quede alineada con las pestañas Desserrez pistolet comme shownSlide Pan Tilt revenir jusqu à ce qu il s aligne avec les onglets Lösen Sie Bolzenschuss als shownSlide Pan Tilt zurück bis sie im Einklang mit den Registerkarten Afrouxe bolter cativeiro como shownSlide Pan Tilt para trás até que alinha com os s...

Page 8: ...nserire e installare cupola O Ring Align If Lanyard attaches to both trim ring and the outside of the housing Si Lanyard concede a ambos y el anillo exterior de la vivienda Si Lanyard attache à la fois l assiette et le ring extérieur de l habitation Wenn Lanyard misst sowohl trim Ring und die außerhalb des Gehäuses Se colhedor atribui a ambos os anéis e os remates de fora da habitação Se Lanyard a...

Page 9: ...remplir jusqu à ce que la valve de décompression s ouvre Setzen Sie die Luftklemme auf das Behälterventil und fangen Sie an zu füllen bis Druckablaßventil sich öffnet Coloque o mandril do ar na válvula do tanque e comece a encher se até que a válvula de escape de pressão abra Disponga il mandrino dell aria sulla valvola del carro armato e cominci a riempirsi fino a che la valvola limitatrice della...

Page 10: ...NG SETTINGS FOR RECEIVER DRIVER UNITS DIPSWITCHES The dipswitches serve a dual purpose First they control the address of the pan tilt when operated via RS485 Second they control the alarm and display functions for the pan tilt Address changes are made using the dip switches located on the PC board Dipswitches UNIT ADDRESSES FOR 485 CONTROL The dipswitches come factory preset with switch 6 in the o...

Page 11: ...e stored pan tilt zoom focus and backlight settings at the highest available speed Preset Number Function 79 Record Run Pattern 2 80 Record Run Pattern 1 81 Stop Recording Pattern 1 or 2 84 Reset the Camera System 85 Backlight Compensation On 86 Backlight Compensation Off 87 Night Mode 88 Day Mode 89 Auto Iris Auto Day Night 99 Clear All Presets NOTE Erasing the EEPROM will override the other swit...

Page 12: ... 40 92 WSTH02 8 Star washer 5 41 30 VL1411 DDWC10 P T bracket 1 Part Number Description Qty 42 60 1414 DDWC10 pan limits collars 2 43 92 WSFL01 1 4 Flat washer SS 4 44 92 WSSL01 1 4 Split lockwasher SS 4 45 90 BTHH27 1 4 20X3 4 Hex head bolt SS 4 46 60 4010 14 tooth 1 5 belt drive pulley 1 47 60 3012 OMRON SS 5GL2Tr par 4 48 60 4012 36 tooth 1 5 belt drive pulley DD tilt 1 49 90 BTSR19 2 56 X 75 P...

Page 13: ...40 39 38 37 36 35 57 56 55 54 53 67 66 65 64 63 62 61 60 59 58 70 69 68 79 78 77 76 75 52 51 50 49 48 47 46 45 44 43 42 41 ...

Page 14: ...o later than 20ms after the last byte of the message has been received If the message is not understood by the DeputyDome a NACK message will be sent If an inquiry message is successfully received from the host the DeputyDome shall respond with the ACK message as previously described and the inquiry response shall then be transmitted no sooner than 1ms and no later than 100ms after the transmissio...

Page 15: ...ess Assignment Message This six byte command sets the address of the dome The address is in hexadecimal and is contained in bytes 4 and 5 If the address is set to FFH then the unit derives its address from the dipswitch Byte number 1 is the start of message F8 byte number 2 is the device address default 01 and byte number six is the message terminator byte FUNCTION Byte 3 Byte 4 Byte 5 DESCRIPTION...

Page 16: ...lt 01 and byte number five is the message terminator byte FUNCTION Byte 3 Byte 4 DESCRIPTION REQUEST POSITION P Get position ASCII character upper case p followed by the character The response to this command is shown in the table below BYTE DATA DESCRIPTION 1 F8H Sync character 2 Address in hex Camera address 01H DFH 3 P Upper case P 4 A2 MS nibble 30H 3FH Position data is 30H ored with data nibb...

Page 17: ...ion data 9 F0 LS nibble 30H 3FH Position data is 30H ored with data nibble F03 F02 F01 F00 of lens focus position data 10 Terminator and Checksum 80H 8FH Most significant nibble is always 8 Least significant LS nibble is the XOR of all previous bytes LS nibble only except for leading autobaud character F8H 3 8 Lens Position Feedback Commands FUNCTION Byte 3 Byte 4 DESCRIPTION REQUEST POSITION V Ge...

Page 18: ...The camera commands control parameters of camera operation All the Camera commands generate a Latch Status response message FUNCTION Byte 3 Byte 4 DESCRIPTION MANUAL IRIS TOGGLE L M Toggles iris operation between auto iris and manual iris CAMERA POWER TOGGLE L P Toggles camera operation on and off LENS SPEED TOGGLE L L Toggles between high speed and low speed zoom TOGGLE AUX1 AUTO WHITE BALANCE L ...

Page 19: ...wn in the table below BYTE DATA DESCRIPTION 1 F8H Autobaud character 2 Address in hex Camera address 01H DFH 3 S Upper case S 4 P1 MS nibble 30H 3FH Pressure data is 30H ored with data nibble P07 P06 P05 P04 of pressure data 5 P0 LS nibble 30H 3FH Pressure data is 30H ored with data nibble P03 P02 P01 P00 of pressure data 6 T1 MS nibble 30H 3FH Temperature data is 30H ored with data nibble T07 T06...

Page 20: ... Form at www videolarm com productregistration jsp or complete and mail in the bottom portion of this flyer Register your recent Videolarm purchases and benefit from the following Simple and Trouble Free RMA process Added into customer database to receive product updates news Eliminate the need to archive original purchase documents Receipts Purchase Orders etc Main Contact Info First Name Last Na...

Reviews: