background image

www.videolarm.com

P D W 7 C S - 9

Explosion-Proof: Purge/Pressurization Unit

Installation and Operation Instructions for the following models:

PDW7CN-9  IP Network Ready

 7” Explosion-Proof PurgeDome™ Outdoor PTZ Camera   

         

Systems for Hazardous environments UL approved for Class 1, Division II  

 

  

applications.  Includes Purging System and Lines.  With 23x zoom Day/Night 

  

camera, MPEG-4 & MJPEG video compression, Full D1.  Clear dome, with 24Vac  

  

input, heater/ blower 

 
PDW7CS-9  Analog 7” Explosion Proof PurgeDome Outdoor PTZ Camera Systems for Hazardous  
  

environments UL approved for Class 1, Division II applications.  Includes Purging System  

  

and Lines.  With 23x zoom Day/Night camera, MPEG-4 & MJPEG video compression,  

  

Full D1.  Clear dome, with 24Vac input, heater/ blower

 

Before attempting to connect or operate this product, please read these instructions completely.   

To be used with the 81-IN5409 Instruction Manual.

81-IN5410
12-21-2011

© 2011, Moog Videolarm, Inc. All Rights Reserved

Summary of Contents for PurgeDome PDW7CN-9

Page 1: ... video compression Full D1 Clear dome with 24Vac input heater blower PDW7CS 9 Analog 7 Explosion Proof PurgeDome Outdoor PTZ Camera Systems for Hazardous environments UL approved for Class 1 Division II applications Includes Purging System and Lines With 23x zoom Day Night camera MPEG 4 MJPEG video compression Full D1 Clear dome with 24Vac input heater blower Before attempting to connect or operat...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ...spect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the Internat...

Page 4: ...Content of Box PURGE PRESSURIZATION UNIT SUPPLIED 1 4 3 8 POLY TUBING Content of Box PROTECTED CAMERA ENCLOSURE PAN TILT DOME HARDWARE ...

Page 5: ...urized unit 2 fitting are provided as shown in the diagrams ENCLOSURE SUPPLY OUTLET 3 8 Push in Fitting ENCLOSURE REFERENCE INLET 1 4 Push in Fitting PURGED PRESSURIZATION UNIT ELECTRICAL ALARM WIRING CONDUIT AND SEAL Customer Supplied SYSTEM SUPPLY INLET 3 8 SS Compression Fitting 1 2 ...

Page 6: ... Purge Pressurization Unit The Tamper Proof Primary Regulator is intended to prevent tampering while allowing a more stable setpoint to be achieved in the small tightly sealed enclosure where the protective gas flow is critically low and difficult to stabilize A 5 64 Hex Key or Allen Wrench is required to operate When performing Initial Purge Pressurization adjust Primary Regulator to 5 psi Normal...

Page 7: ...AMS DOME PRESURE GAUGE ENCLOSURE ATMOSPHERIC REFERENCE EXP PRESURE SWITCH PROTECTED CAMERA ENCLOSURE REFERENCE SYSTEM SUPPLY INLET SUPPLY PRIMARY REGULATOR SECONDARY REGULATOR FLOWMETER TUBING CONNECTION DIAGRAMS ENCLOSURE SUPPLY OUTLET ENCLOSURE REFERENCE INLET SYSTEM SUPPLY INLET PEPPERL FUCHS PURGE PRESSURIZATION UNIT 5 6 ...

Page 8: ...ary SCFH flowmeter is unnecessary Use the permanently installed flowmeter on the swing panel in the Purge Pressurization Unit See supplied Model 1001A Installation and Operation Manual for additional installation and operation information CONNECTION SIZES LENGTHS BENDS System Supply Camera Supply Camera Reference 3 8 OD SS Tubing SUPPLIED SUPPLIED Fully Reamed 3 8 Poly Tubing 1 4 Poly Tubing MAXIM...

Page 9: ...marked on the board and plugged into the corresponding voltage for the input single phase Attach unit securely to the wall mount using 4 3 8 or 8mm hardware not supplied WALL MOUNT The power box may be pole mounted with the pole support clips Stainless steel straps not provided 10 11 12 120Vac Input 240Vac Input Main Switch Connect incoming ground to ground post as shown 13 ...

Page 10: ...igned for 3 phase or 208V systems 24Vac Power To Housing Optional 24Vac Output Main Switch Connect Housing Power Remove Pan Tilt from shipping carton Install in base bracket in housing To secure in place tighten captive screw See S View Pan Tilt instructions for additional details If required the Pan Tilt and dome may be installed before mounting the entire assembly CAPTIVE SCREW 14 15 16 ...

Page 11: ... Description 1 RP65PT851200 PAN TILT 2 PR25DCP71000 TRIM RING ASSEMBLY WITH CLEAR DOME To install the dome align the tabs and twist counter clockwise to secure Hand tighten the screws on the dome Recommended torque 12 inches lb 1 35Nm 17 18 ...

Page 12: ...Housings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via the Online Product Registration Form at www videolarm com productregistration jsp Register your recent Moog Videolarm purchases and benefit from the following Simple and Trouble Free RMA process Add...

Reviews: