- 5 -
JVC:
The JVC unitized camera requires use of the adapter
bracket supplied in the housing packet. Attach (4) of the
standoffs to the main housing bracket. Put the adapter
bracket in place and secure it with (4) 8 x 32 x 3/8” bolts and
star washers. Place (4) additional 1/2" standoffs on the
outside bolt pattern on the adapter bracket. Attach the JVC
quick-release bracket unit with (4) 8 x 32 x 3/8” bolts and
lock washers. Wire as directed by the manufacturer. A
wiring color code is supplied on page 3.
JVC
Trinus:
The Trinus unitized camera mounts directly to the main
housing bracket. Orient the bracket as shown in the
diagram and attach using (3) 8 x 32 x 3/8” bolts and star
washers. Wire as directed by the manufacturer. A wiring
color code is supplied on page 3.
Trinus
Sensormatic/ AD Ultra/ Delta Dome™:
The Ultra Dome™
unitized camera requires use of the adapter bracket
supplied in the housing packet. Attach (4) of the 1/2"
standoffs to the main housing bracket. Put the adapter
bracket in place and secure it with (4) 8 x 32 x 3/8” bolts
and star washers. Align the Ultra Dome™ quick release
bracket as shown and secure in place with (2) 10 x 32 x
3/8” bolts and star washers. Wire as directed by the
manufacturer. A wiring color code is supplied on page 3.
Sensormatic
Pelco Spectra Dome™:
This bracket attaches directly to the
main housing bracket. Align as shown. Note the position
of the blowers on the flat areas of the quick-release.
Secure in place using (3) 6 x 32 x 3/8 bolts and star
washers. Wire as directed by the manufacturer. A wiring
color code is supplied on page 3.
Pelco
Fixed Bracket:
The housing is provided with (
4) 1/4
x
20
insert
s
for mounting a fixed bracket. Attach as shown.
Connect
video
and 24 VAC camera power. (Red and
Orange wires.)
*
You should use a minimum
of two bolts to attach
the housing.
Fixed bracket
INSTALLING VARIOUS MANUFACTURER'S QUICK RELEASE BRACKETS