Moog ACV with CANopen bus interface
6 Signal routing and scaling
Analog inputs
B99224-DV018-D-211, Rev. A, October 2018
89
6.4.4 Analog input 3
6.4.4.1 Object 0x3218: Input type
This input type describes the supported electrical signal for the analog input 3.
Value description
6.4.4.2 Object 0x321C: Actual value
Actual value of the analog input 3.
6.4.5 Analog input 4
6.4.5.1 Object 0x3220: Input type
This input type describes the supported electrical signal for the analog input 4.
Value description
6.4.5.2 Object 0x3224: Actual value
Actual value of the analog input 4.
6.4.6 Internal pressure transducer input
The internal pressure transducer input is located in the servo valve port A. This transducer can also be used
as input for the controller.
Chapter "6.3.9 Transducer interface definition", page 74
AnalogInput3
Index
Sub-index
Parameter name
Data type
Access
Persis-
tence
Value range
Default
0x3218
0
AnaInpType3
INT8
rw
Y
INT8
2
AnalogInput3
Index
Sub-index
Parameter name
Data type
Access
Persis-
tence
Value range
Default
0x321C
0
AnaInpActualValue3
INT16
ro
-
INT16
None
AnalogInput4
Index
Sub-index
Parameter name
Data type
Access
Persis-
tence
Value range
Default
0x3220
0
AnaInpType4
INT8
rw
Y
INT8
2
AnalogInput4
Index
Sub-index
Parameter name
Data type
Access
Persis-
tence
Value range
Default
0x3224
0
AnaInpActualValue4
INT16
ro
-
INT16
None