Moog ACV with CANopen bus interface
7 Servo valve functions
Pressure setpoint conditioning / demand value generator
B99224-DV018-D-211, Rev. A, October 2018
159
7.4.1 Object 0x6390: Demand value
The demand value indicated by this parameter is generated from the #PressureSetpoint# by means of the
functions in the demand value generator and forwarded to the pressure controller.
Chapter "2.4.3 Units and prefix parameter", page 12
7.4.2 Object 0x6391: Reference value
The reference value is the value that corresponds to 100 % of the input signal. This means that a 100 % pres-
sure input signal is equal to 16384 increments and a –100 % input signal is equal to –16384 increments. This
parameter depends on the controller hardware. It can be used by the field bus master to scale the setpoint
values.
Chapter "2.4.3 Units and prefix parameter", page 12
ValvePressureControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6390
1
PrsDemandValue
INT16
ro
N
INT16
None
0x6390
2
Unit
UINT8
ro
-
UINT8
0
0x6390
3
Prefix
INT8
ro
-
INT8
0
ValvePressureControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x6391
1
PrsReferenceValue
INT16
ro
-
INT16
16384
0x6391
2
Unit
UINT8
ro
-
UINT8
0
0x6391
3
Prefix
INT8
ro
-
INT8
0