Moog ACV with CANopen bus interface
7 Servo valve functions
Pressure setpoint conditioning / demand value generator
B99224-DV018-D-211, Rev. A, October 2018
164
7.4.5.2.1 Object 0x63B1: Acceleration time
This parameter defines the output signal's maximum rate of change. The acceleration time corresponds to the
time the signal needs for a change from 0 to 100 % as shown in the figure above. The acceleration time can
be specified with a resolution of 1 s, 100 ms, 10 ms or 1 ms.
Chapter "2.4.3 Units and prefix parameter", page 12
7.4.5.3 Two-quadrant ramp (ramp type 2)
This function limits the input signal's rate of change to the defined <AccelerationTime> (0x63B1) and
<DeccelerationTime> (0x63B4).
This ramp type is active, if the parameter <Type> (0x63B0) is set to 2.
Figure 76: Ramp type 2
7.4.5.3.1 Object 0x63B1: Acceleration time
This parameter is the same as the acceleration time for ramp type 1.
Chapter "7.4.5.2.1 Object 0x63B1: Acceleration time", page 164
ValvePressureControl_DemandValueGenerator_Ramp
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value
range
Default
0x63B1
1
AccelerationTime
UINT16
rw
Y
UINT16
0
0x63B1
2
Unit
UINT8
ro
-
UINT8
3
0x63B1
3
AccelerationTime_Prefix
INT8
rw
Y
–4…0
–3
t
input
+ 100 %
- 100 %
t
output
+ 100 %
- 100 %
<DecelerationTime>
(0x63B4)
<AccelerationTime>
(0x63B1)